Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CINTAS CORPORATION

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of CINTAS CORPORATION in 8411 KELSO DRIVE, ESSEX, MD 21221 (NAICS 561990). OSHA activity number 314170622.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cintas Corporation — free Get an email when a new federal OSHA severe-injury report for Cintas Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
CINTAS CORPORATION
Site address
8411 KELSO DRIVE
City
ESSEX
State
MD
ZIP
21221
Mailing
6770 OAK HALL LANE SUITE 107, COLUMBIA, MD 21045
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561990
SIC code (legacy)
7389
Employees
4
Ownership type
A

1 citation on file for this inspection.

50104 A

Serious Gravity 07 1 instance 4 exposed
Issued
Jul 22, 2010
Abate by
Jul 29, 2010
Penalty
Initial $2,975 · Current $2,975
Labor and Employment Article, Section 5-104(a): The employer did not
furnish employment and a place of
employment which were free from recognized hazards that were causing or
likely to cause death or serious
physical harm to employees:
(a)Date of Violation:05/14/10
Location:Shredding Area
Equipment:Two SEM, Model: #F-034 Fan Type Evacuation Systems, Serial:
#9511 and #8358
Condition:Employees were exposed to dust explosion or other fire hazards
due to the potential
ignition of combustible paper dust in a dust collection system that was
located in the
work area; was not effectively bonded; and not protected by containment,
suppression,
inerting, or other methods of preventing the propagation of a deflagration
or fire into
areas, occupied by employees.
Among other methods, one feasible and acceptable means of abatement is to
comply with the guidelines,
outlined in the National Fire Protection Association (NFPA) 654 Standard
for
the Prevention of Fire and Dust
Explosions from the Manufacturing, Processing, and Handling of Combustible
Particulate Solids.
Abatement documentation (photographs, receipts, copies of programs,
training certification, etc.)
is required for this item.
Recent events (2)
  • — F (S) $2975.00
  • — Z (S) $2975.00

View Cintas Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314170622.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.