LANCASTER, PA —
OSHA Inspection: THERMAL SOLUTIONS PRODUCTS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of THERMAL SOLUTIONS PRODUCTS, LLC in 1175 MANHEIM PIKE, LANCASTER, PA 17601 (NAICS 332410). OSHA activity number 314244153.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THERMAL SOLUTIONS PRODUCTS, LLC
- Site address
- 1175 MANHEIM PIKE
- City
- LANCASTER
- State
- PA
- ZIP
- 17601
- Mailing
- 1175 MANHEIM PIKE, LANCASTER, PA 17601
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332410
- SIC code (legacy)
- 3443
- Employees
- 40
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Apr 6, 2011
- Abate by
- May 9, 2011
- Penalty
- Initial $3,570 · Current $2,675 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard from flying polyvinyl chloride (PVC) pipe fragments: (a)Burner Room - The employer used schedule 40 polyvinyl chloride (PVC) piping of varying diameters to transport compressed air for use in the burner manufacturing process, exposing employees to a struck-by hazard from flying fragments associated with such use of PVC piping in above ground installations. According to the Plastic Pipe Institute and the Plastic Pipe and Fittings Association, PVC piping does not possess shatter resistant properties, and failure of the piping presents a serious hazard to employees from resultant flying shards or pipe fragments which become rapidly propelled by the released energy of a suddenly decompressing gas, as happened on March 1, 2011 when PVC piping carrying compressed air in the Burner Room did burst and shatter. Among other methods, feasible and acceptable abatement methods to correct this hazard include encasing above ground installations of PVC piping in metal piping as specified in the American Society of Mechanical Engineers Code for Pressure Piping: Gas Transmission and Distribution Piping Systems (ASME B31.8-2010) or using only certain acrylonitrile butadiene styrene (ABS) plastic piping specifically marked as approved for transporting compressed air. VERIFICATION REQUIREDTION
Recent events (2)
- — I (S) $2675.00
- — Z (S) $3570.00
More inspections at Thermal Solutions Products, LLC
View Thermal Solutions Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332410)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314244153.