OSHA Inspection: THERMAL SOLUTIONS PRODUCTS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THERMAL SOLUTIONS PRODUCTS, LLC in 1175 MANHEIM PIKE, LANCASTER, PA 17601 (NAICS 332410). OSHA activity number 314244153.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thermal Solutions Products, LLC — free Get an email when a new federal OSHA severe-injury report for Thermal Solutions Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1175 MANHEIM PIKE
City
LANCASTER
State
PA
ZIP
17601
Mailing
1175 MANHEIM PIKE, LANCASTER, PA 17601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
SIC code (legacy)
3443
Employees
40
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 1 exposed
Issued
Apr 6, 2011
Abate by
May 9, 2011
Penalty
Initial $3,570 · Current $2,675 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to a struck-by hazard from flying
polyvinyl chloride (PVC) pipe fragments:
(a)Burner Room - The employer used schedule 40 polyvinyl chloride (PVC)
piping of varying
diameters to transport compressed air for use in the burner manufacturing
process, exposing
employees to a struck-by hazard from flying fragments associated with such
use of PVC piping
in above ground installations.  According to the Plastic Pipe Institute
and the Plastic Pipe and
Fittings Association, PVC piping does not possess shatter resistant
properties, and failure of
the piping presents a serious hazard to employees from resultant flying
shards or pipe
fragments which become rapidly propelled by the released energy of a
suddenly decompressing
gas, as happened on March 1, 2011 when PVC piping carrying compressed air
in the Burner
Room did burst and shatter.
Among other methods, feasible and acceptable abatement methods to correct
this hazard include
encasing above ground installations of PVC piping in metal piping as
specified in the American
Society of Mechanical Engineers Code for Pressure Piping:  Gas
Transmission and Distribution Piping
Systems (ASME B31.8-2010) or using only certain acrylonitrile butadiene
styrene (ABS) plastic piping
specifically marked as approved for transporting compressed air.
VERIFICATION REQUIREDTION
Recent events (2)
  • — I (S) $2675.00
  • — Z (S) $3570.00

View Thermal Solutions Products, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314244153.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.