Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: PELICAN WIRE CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PELICAN WIRE CO. in 3650 SHAW BLVD, NAPLES, FL 34117 (NAICS 331422). OSHA activity number 314267303.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pelican Wire CO. for free Get an email when a new federal OSHA severe-injury report for Pelican Wire CO. is published. One employer, no account, unsubscribe in one click.
Establishment
PELICAN WIRE CO.
Site address
3650 SHAW BLVD
City
NAPLES
State
FL
ZIP
34117
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331422
SIC code (legacy)
3357
Employees
46
Ownership type
Private (A)

12 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 5 instances 2 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011
Penalty
Initial $2,975 · Current $2,231 Reduced
Section 5(a)1 of the Occupational Safety and Health Act of 1970:  The
employer did not furnish
to each of his employees employment and a place of employment which were
free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees in that employees were exposed to:
On or about 11/16/2010, at Pelican Wire Co., Naples, FL.
a. At the maintenance department, an employee was exposed to caught by
and struck by hazards while working with a lathe (Birmingham, Model
CT-144G) that lacked a provision to prevent automatic restart upon
restoration of power.
b. At the maintenance department, an employee was exposed to caught by
and struck by hazards while working with a milling machine (Bridgeport,
Model 8F) that lacked a provision to prevent automatic restart upon
restoration of power.
c. At the maintenance department, an employee was exposed to caught by
and struck by hazards while working with a milling machine (Ultima,
Property #111003) that lacked a provision to prevent automatic restart
upon restoration of power.
d. At the maintenance department, an employee was exposed to caught by
and struck by hazards while working with a drill press (Walker-Turner,
Serial #111017) that lacked a provision to prevent automatic restart upon
restoration of power.
e. At the maintenance department, an employee was exposed to caught by
and struck by hazards while working with a lathe (Enco, Model 111-1450)
that lacked a provision to prevent automatic restart upon restoration of
power.
Among the feasible and useful methods to correct the hazard is installing a
magnetic switch to prevent automatic restart upon restoration of power
after a
power failure.
Note:Certification of abatement must be submitted for this citation
item.ion
Recent events (2)
  • · I (S) $2231.00
  • · Z (S) $2975.00

1910.212 A01

Serious Gravity 05 34 instances 4 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011
Penalty
Initial $2,975 · Current $2,231 Reduced
Recent events (2)
  • · I (S) $2231.00
  • · Z (S) $2975.00

1910.212 B

Serious Gravity 01 5 instances 1 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011
Penalty
Initial $1,785 · Current $1,339 Reduced
Recent events (2)
  • · I (S) $1339.00
  • · Z (S) $1785.00

1910.219 C04 I

Serious Gravity 01 4 instances 2 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011
Penalty
Initial $1,785 · Current $1,339 Reduced
Recent events (2)
  • · I (S) $1339.00
  • · Z (S) $1785.00

1910.219 E03 I

Serious Gravity 01 3 instances 2 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011
Penalty
Initial $1,785 · Current $1,339 Reduced
Recent events (2)
  • · I (S) $1339.00
  • · Z (S) $1785.00

1910.219 F01

Serious Gravity 05 55 instances 2 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011
Penalty
Initial $2,975 · Current $2,231 Reduced
Recent events (2)
  • · I (S) $2231.00
  • · Z (S) $2975.00

1910.219 F03

Serious Gravity 01 2 instances 2 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011
Penalty
Initial $1,785 · Current $1,339 Reduced
Recent events (2)
  • · I (S) $1339.00
  • · Z (S) $1785.00

1910.304 G05

Serious Gravity 01 2 instances 1 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011
Penalty
Initial $1,785 · Current $1,339 Reduced
Recent events (2)
  • · I (S) $1339.00
  • · Z (S) $1785.00

1904.29 A

Other-than-serious Gravity 00 3 instances
Issued
Apr 13, 2011
Abate by
Apr 27, 2011

1910.22 D01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011

1910.133 A01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Apr 13, 2011
Abate by
Apr 27, 2011

1910.1200 G08

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Apr 13, 2011
Abate by
Apr 20, 2011

View Pelican Wire CO.'s full OSHA safety record →