SYRACUSE, NY —
OSHA Inspection: OBERDORFER, L.L.C.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OBERDORFER, L.L.C. in 6259 THOMPSON RD., SYRACUSE, NY 13206 (NAICS 331524). OSHA activity number 314347048.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OBERDORFER, L.L.C.
- Site address
- 6259 THOMPSON RD.
- City
- SYRACUSE
- State
- NY
- ZIP
- 13206
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331524
- SIC code (legacy)
- 3365
- Employees
- 56
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
26 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING STRUCK-BY THE LOAD SHOULD THE HOIST FAIL: a)Shell Sand area, on or about 09/07/2010: A Gardner Denver, 2-ton overhead pneumatic hoist was being operated in the foundry without a safety latch on the hoist hook and no frequent daily inspection had been performed by an operator or other designated person. b)Sand Molding area, on or about 09/07/2010: A Yale 5-ton overhead pneumatic hoist was being operated in the foundry without a safety latch on the hoist hook and no frequent daily inspection had been performed by an operator or other designated person. c)Impregnation cell area, on or about 09/07/2010: A Coffing 1/2-ton overhead pneumatic hoist was being used in the foundry without a safety latch on the hoist hook and no frequent daily inspection had been performed by an operator or other designated person. Among other methods, several feasible and acceptable abatement methods to correct this hazard are to: 1.Repair or replace the safety latches and ensure they meet the requirement of the ASME B30.16-2007, Overhead Hoists, Section 16-.1.2.9. 2.Conduct frequent daily inspections during operation of the of the hoists for missing or defective equipment in accordance with ASME B30.16-2007, Overhead Hoists, Section 16-2.1.1 Inspections. Abatement certification must be submitted for these items.
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.22 B01
- Issued
- Jan 27, 2011
- Abate by
- Feb 9, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.22 C
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.36 D01
- Issued
- Jan 27, 2011
- Abate by
- Feb 4, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.37 B02
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.37 B04
- Issued
- Jan 27, 2011
- Abate by
- Feb 4, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.132 D01 I
- Issued
- Jan 27, 2011
- Abate by
- Feb 4, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.176 B
- Issued
- Jan 27, 2011
- Abate by
- Feb 4, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.178 A04
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
- Penalty
- Initial $5,000 · Current $3,000 Reduced
Recent events (2)
- — J (S) $3000.00
- — Z (S) $5000.00
1910.178 A05
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.178 L03 IG
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.212 A01
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.219 D01
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.219 E01 I
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.242 B
- Issued
- Jan 27, 2011
- Abate by
- Feb 9, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.303 B02
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
- Penalty
- Initial $5,000 · Current $3,000 Reduced
Recent events (2)
- — J (S) $3000.00
- — Z (S) $5000.00
1910.305 A02 VC
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.305 G01 IVA
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.305 G01 IVB
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.305 G02 II
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.305 G02 III
- Issued
- Jan 27, 2011
- Abate by
- Mar 1, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.303 G02 I
- Issued
- Jan 27, 2011
- Abate by
- Feb 9, 2011
- Penalty
- Initial $5,000 · Current $3,000 Reduced
Recent events (2)
- — J (S) $3000.00
- — Z (S) $5000.00
1910.305 B01 II
- Issued
- Jan 27, 2011
- Abate by
- Feb 4, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.305 B02 I
- Issued
- Jan 27, 2011
- Abate by
- Feb 4, 2011
Recent events (2)
- — J (S)
- — Z (S)
1910.304 G05
- Issued
- Jan 27, 2011
- Abate by
- Feb 4, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — J (S) $1500.00
- — Z (S) $2500.00
1910.305 A02 IX
- Issued
- Jan 27, 2011
- Abate by
- Feb 4, 2011
- Penalty
- Initial $2,000 · Current $1,200 Reduced
Recent events (2)
- — J (S) $1200.00
- — Z (S) $2000.00
More inspections at Oberdorfer, L.L.C.
View Oberdorfer, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 331524)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314347048.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.