Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICHEM OF OHIO, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AMERICHEM OF OHIO, INC. in 723 COMMERCE DRIVE, CONCORD, NC 28025 (NAICS 325211). OSHA activity number 314517160.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Americhem of Ohio, INC. — free Get an email when a new federal OSHA severe-injury report for Americhem of Ohio, INC. is published. One employer, no account, unsubscribe in one click.
Site address
723 COMMERCE DRIVE
City
CONCORD
State
NC
ZIP
28025
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
SIC code (legacy)
2821
Employees
132
Ownership type
A
Industry flags
Manufacturing health.

2 citations on file for this inspection.

95012901

Deleted Serious 6 instances 12 exposed
Issued
Jul 16, 2010
Abate by
Aug 11, 2010
Penalty
Initial $5,600 · Current $5,600
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North
Carolina:  The employer did not furnish employment and a place of
employment which were
free from recognized hazards that were causing or likely to cause death or
serious physical harm
to employees in that employees were exposed to fire and explosion hazards:
a)facility, air-material separators were not interconnected and grounded
to the metal
drums used to collect the dust.
One feasible and acceptable method to correct this hazard is to install
explosion protection in
accordance with National Fire Protection Association (NFPA) 654, Standard
for the Prevention
of Fire and Dust Explosions from Manufacturing, Processing, and handling
of Combustible Dust
Particulate Solids (2006), section 9.3.1.3 "Bonding and grounding with a
resistance of less than
1.0x106 ohms to ground shall be provided for conductive components."
Recent events (2)
  • — I (S) $5600.00
  • — Z (S) $5600.00

95012901

Serious 5 instances 12 exposed
Issued
Jul 16, 2010
Abate by
May 11, 2011
Penalty
Initial $5,600 · Current $3,650 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North
Carolina:  The employer did not furnish employment and a place of
employment which were
free from recognized hazards that were causing or likely to cause death or
serious
physical harm
to employees in that employees were exposed to a fire and explosion
hazard:
a)facility, air-material separators used to collect and filter
contaminated air did not
have equipment to isolate a dust deflagration.
Feasible and acceptable methods to correct these hazards is to install
explosions in accordance
with national Fire Protection Association (NFPA) 654, Standard for the
Prevention of Fire and
Dust Explosions from the Manufacturing, Processing, and handling of
Combustible Dust
Particulate Solids (2006), paragraph 7.11.1.1, 7.1.4.1, 7.13.1.1.1, and
7.13.1.7.1.
Recent events (3)
  • — P (S) $3650.00
  • — I (S) $3650.00
  • — Z (S) $5600.00

View Americhem of Ohio, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314517160.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.