Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COUNTRY VILLAGE POWER EQUIPMENT, LLC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of COUNTRY VILLAGE POWER EQUIPMENT, LLC. in 3301 PAUL BUCHMAN HWY, PLANT CITY, FL 33565 (NAICS 444210). OSHA activity number 314623380.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Country Village Power Equipment, LLC. — free Get an email when a new federal OSHA severe-injury report for Country Village Power Equipment, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
3301 PAUL BUCHMAN HWY
City
PLANT CITY
State
FL
ZIP
33565
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444210
SIC code (legacy)
7699
Employees
8
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 3 exposed
Issued
Jul 28, 2010
Abate by
Aug 30, 2010
Penalty
Initial $800 · Current $800
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognize hazards that
were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to the hazard of being struck by fragments of
Thermoplastic
Polyvinyl Chloride (PVC) plastic pipe in the event that the PVC plastic
pipe ruptures.
a. On or about 06/07/2010. Equipment and golf cart repair shops - PVC
piping was used in
exposed above ground locations to transport compressed air for the
operation of air operated
tools. The use of PVC plastic pipes in exposed above ground locations is
not recommended
by the Plastic Pipe Institute, and such use is prohibited by ANSI/ASME
B31.8-1986, Gas
Transmission and Distribution Piping Systems Standards.
Among other methods, two feasible and acceptable abatement methods to
correct this hazard
are:
1)Replace all existing PVC pipes and fittings with cast iron materials, or
other
types of metal piping, which are rated to transport compressed air safely
in exposed
above ground locations.
2)Replace all existing PVC pipes and fitting with shatter resistant
Acrylonitrile-
Butadiene-Styrene (ABS) pipe and fittings, which are manufactured for
above ground
use of compressed air.

1910.151 C

Serious Gravity 01 1 instance 4 exposed
Issued
Jul 28, 2010
Abate by
Aug 5, 2010
Penalty
Initial $600 · Current $600

1910.157 C01

Serious Gravity 01 1 instance 4 exposed
Issued
Jul 28, 2010
Abate by
Aug 5, 2010
Penalty
Initial $600 · Current $600

1910.212 A01

Serious Gravity 01 1 instance 3 exposed
Issued
Jul 28, 2010
Abate by
Aug 10, 2010
Penalty
Initial $600 · Current $600

1910.212 B

Serious Gravity 01 1 instance 3 exposed
Issued
Jul 28, 2010
Abate by
Aug 5, 2010
Penalty
Initial $600 · Current $600

1910.157 G01

Repeat Gravity 01 1 instance 4 exposed
Issued
Jul 28, 2010
Abate by
Aug 15, 2010
Penalty
Initial $1,200 · Current $1,200

1910.215 A04

Repeat Gravity 01 1 instance 3 exposed
Issued
Jul 28, 2010
Abate by
Aug 10, 2010
Penalty
Initial $1,200 · Current $1,200

View Country Village Power Equipment, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314623380.