CHICAGO, IL ·
OSHA Inspection: TEMPEL STEEL COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TEMPEL STEEL COMPANY in 5454 N. WOLCOTT AVENUE, CHICAGO, IL 60640 (NAICS 332116). OSHA activity number 314686395.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEMPEL STEEL COMPANY
- Site address
- 5454 N. WOLCOTT AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60640
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- SIC code (legacy)
- 3469
- Employees
- 785
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 23, 2010
- Abate by
- Nov 26, 2010
- Penalty
- Initial $2,250 · Current $1,575 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to amputation from rotating/moving blades: a) Storage Room Area - Provision was not made to prevent the vertical metal cutting band saw, from automatically restarting upon restoration of power after a power source failure. b) Tool Room Area - Provision was not made to prevent the vertical metal cutting band saw, from automatically restarting upon restoration of power after a power source failure. Among others methods, one feasible and acceptable means of abatement in an event of interruption in the electrical supply to the saw would be to provide an electrical device that is designed to prevent the saw from restarting automatically when power is restored, such as a magnetic restart or similar device as prescribed by the American National Standard Institute for Metal Sawing Machines, ANSI B11.10-2003, Section 6.11. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (S) $1575.00
- · Z (S) $2250.00
1910.147 C06 I
- Issued
- Nov 23, 2010
- Abate by
- Dec 24, 2010
- Penalty
- Initial $1,350 · Current $945 Reduced
Recent events (2)
- · I (S) $945.00
- · Z (S) $1350.00
1910.212 A01
- Issued
- Nov 23, 2010
- Abate by
- Nov 26, 2010
- Penalty
- Initial $2,250 · Current $1,575 Reduced
Recent events (2)
- · I (S) $1575.00
- · Z (S) $2250.00
1910.217 C02 IA
- Issued
- Nov 23, 2010
- Abate by
- Nov 26, 2010
- Penalty
- Initial $4,500 · Current $3,150 Reduced
Recent events (2)
- · I (S) $3150.00
- · Z (S) $4500.00
1910.217 C02 IV
- Issued
- Nov 23, 2010
- Abate by
- Nov 26, 2010
More inspections at Tempel Steel Company