ST. LOUIS, MO —
OSHA Inspection: KERRY INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of KERRY INC. in 8155 NEW HAMPSHIRE AVE, ST. LOUIS, MO 63123 (NAICS 311812). OSHA activity number 314989211.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KERRY INC.
- Site address
- 8155 NEW HAMPSHIRE AVE
- City
- ST. LOUIS
- State
- MO
- ZIP
- 63123
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- SIC code (legacy)
- 2051
- Employees
- 320
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 7, 2011
- Abate by
- Aug 23, 2011
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of unintentional machine movement: At the establishment, employees were exposed to a struck-by hazard from a scissors lift due to unplanned movement. On or about 01/14/11, a fatality occurred involving a Skyjack Scissors Lift. Skyjack Scissors Lift (model number SJIII 3219, serial number 220189498) unexpectedly traveled in reverse direction and pinned an employee between the Skyjack Scissors Lift and a second Skyjack Scissors Lift (model number SJ 3220, serial number 62405). One method to correct this apparent hazard is to implement lift start-up and shut-down procedures in accordance with the Operating Manual. DISCLAIMER: a)The employer is not limited to the abatement method(s) suggested by OSHA. b)The employer is responsible for selecting and implementing an effective abatement method. Abatement certification and documentation are required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — J (S) $7000.00
- — Z (S) $7000.00
5(a)(1)
- Issued
- Jul 7, 2011
- Abate by
- Aug 23, 2011
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of unintentional machine movement: At the establishment, employees were exposed to a struck-by hazard from a scissors lift due to unplanned movement. On or about 01/14/11, a fatality occurred involving a Skyjack Scissors Lift. Skyjack Scissors Lift (model number SJIII 3219, serial number 220189498) unexpectedly traveled in reverse direction and pinned an employee between the Skyjack Scissors Lift and a second Skyjack Scissors Lift (model number SJ 3220, serial number 62405). One method to correct this apparent hazard is to conduct pre-start inspections (pre-operational inspections). Table 2.7 of the Operating Manual for the Skyjack Scissors Lift (model number SJIII 3219, serial number 22018949, manufactured in 2009) provides a detailed operator's checklist that meets the ANSI/SIA A92.6-2006 Section 7.3.3 Pre-start inspection. Before use each day or at the beginning of each shift, the aerial platform shall be given a visual inspection and a functional test including but not limited to the following: (1)Operating and emergency controls. (2)Safety devices. (3)Air, hydraulic and fuel system leaks. (4)Cables and wiring harness. (5)Loose or missing parts. (6)Tires and wheels. (7)Placards, warning, control markings, and operating manual(s). (8)Outriggers, stabilizers, and other structures. (9)Guardrail system. (10)Items specified by the manufacturer. DISCLAIMER: a)The employer is not limited to the abatement method(s) suggested by OSHA. b)The employer is responsible for selecting and implementing an effective abatement method. Abatement certification and documentation are required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — J (S)
- — Z (S)
5(a)(1)
- Issued
- Jul 7, 2011
- Abate by
- Aug 23, 2011
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of unintentional machine movement. At the establishment, employees were exposed to a struck-by hazard from a scissors lift due to unplanned movement. On or about 01/14/11, a fatality occurred involving a Skyjack Scissors Lift. Skyjack Scissors Lift (model number SJIII 3219, serial number 220189498) unexpectedly traveled in reverse direction and pinned an employee between the Skyjack Scissors Lift and a second Skyjack Scissors Lift (model number SJ 3220, serial number 62405). One method to correct this apparent hazard is to conduct frequent and annual inspections. Table 2.6 of the Operating Manual for the Skyjack Scissors Lift (model number SJIII 3219, serial number 22018949, manufactured in 2009) provides a detailed Maintenance and Inspection Schedule for Yearly, 3 months or 150 hours, and Daily checklist that meets the ANSI/SIA A92.6-2006 Section 7.3.1 Frequent Inspection and Section 7.3.2 Annual inspection requirements. The annual inspection date must also be included on the Annual Inspection Record decal located on the scissor assembly. DISCLAIMER a)The employer is not limited to the abatement method(s) suggested by OSHA b)The employer is responsible for selecting and implementing an effective abatement method. Abatement certification and abatement documentation are required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — J (S)
- — Z (S)
More inspections at Kerry INC.
View Kerry INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314989211.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.