KENOSHA, WI —
OSHA Inspection: P.O.P. MANUFACTURING, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of P.O.P. MANUFACTURING, INC. in 9009 SHERIDAN RD., KENOSHA, WI 53143 (NAICS 337215). OSHA activity number 315119842.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- P.O.P. MANUFACTURING, INC.
- Site address
- 9009 SHERIDAN RD.
- City
- KENOSHA
- State
- WI
- ZIP
- 53143
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337215
- SIC code (legacy)
- 2541
- Employees
- 18
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- May 24, 2011
- Abate by
- Apr 30, 2012
- Penalty
- Initial $4,200 · Current $2,100 Reduced
M102
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm including severe burns to employees where employees were exposed to dust explosion, deflagration, or other fire hazards from dust collectors being located inside a building: (a)There was a 4 barrel Dustek enclosure-less dust collector system operating in the production area within 20 feet of employees at work stations used to collect wood dust from the routers and edge binder. No fire suppression or spark arresting equipment was available for the unit or ductwork for the exhaust. (b)There was a 4 barrel Dustek enclosure-less dust collector system operating in the production area within 20 feet of employees at work stations used to collect wood dust from the saw. No fire suppression or spark arresting equipment was available for the unit or ductwork for the exhaust. (c)There was a Donaldson Torit enclosure-less dust collector system Model 36 operating inside of an adjacent room from the main production area within 20 feet of employees working at table saws and other woodworking equipment used to collect wood dust from the equipment. No fire suppression or spark arresting equipment was available for the unit or ductwork for the exhaust. AMONG OTHER METHODS, A FEASIBLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO RELOCATE THE DUST COLLECTION SYSTEMS OUTSIDE THE BUILDING OR IMPLEMENT THE PROTECTIVE MEASURES SET FORTH IN THE NATIONAL FIRE PROTECTION ASSOCIATION STANDARD FOR THE PREVENTION OF FIRES AND EXPLOSIONS IN WOODWORKING FACILITIES. NFPA 664 (2007 EDITION), SPECIFICALLY SECTION 8.2.2.5.1.4 WHICH ADDRESSES DUST COLLECTORS. Certification, and documentation/evidence of abatement is required. Certification of abatement is required by 29 CFR Part 1903 and is to be submitted within ten (10) calendar days after the abatement date.ment
Recent events (2)
- — I (S) $2100.00
- — Z (S) $4200.00
1910.22 A01
- Issued
- May 24, 2011
- Abate by
- May 27, 2011
- Penalty
- Initial $3,600
M102
Recent events (2)
- — I (O)
- — Z (S) $3600.00
1910.1000 A02
- Issued
- May 24, 2011
- Abate by
- Jan 8, 2012
- Penalty
- Initial $2,400
9135
Recent events (2)
- — I (O)
- — Z (S) $2400.00
1910.1000 E
- Issued
- May 24, 2011
- Abate by
- Jan 8, 2012
9135
Recent events (2)
- — I (O)
- — Z (S)
1910.134 D01 II
- Issued
- May 24, 2011
- Abate by
- Aug 1, 2012
Recent events (2)
- — I (O)
- — Z (S)
1910.134 C01
- Issued
- May 24, 2011
- Abate by
- Aug 1, 2011
Recent events (2)
- — I (O)
- — Z (S)
1910.134 E01
- Issued
- May 24, 2011
- Abate by
- Aug 1, 2011
Recent events (2)
- — I (O)
- — Z (S)
1910.134 F01
- Issued
- May 24, 2011
- Abate by
- Aug 1, 2011
Recent events (2)
- — I (O)
- — Z (S)
1910.134 K01
- Issued
- May 24, 2011
- Abate by
- Aug 1, 2011
Recent events (2)
- — I (O)
- — Z (S)
1910.107 B09
- Issued
- May 24, 2011
- Abate by
- Jun 3, 2011
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 E01
- Issued
- May 24, 2011
- Abate by
- Jun 10, 2011
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 F05
- Issued
- May 24, 2011
- Abate by
- Jun 3, 2011
Recent events (2)
- — I (O)
- — Z (O)
More inspections at P.O.P. Manufacturing, INC.
View P.O.P. Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337215)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315119842.