FRANKLIN PARK, IL —
OSHA Inspection: JEWEL FOOD STORES, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of JEWEL FOOD STORES, INC. in 2020 N 17TH AVE., FRANKLIN PARK, IL 60131 (NAICS 493110). OSHA activity number 315180745.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JEWEL FOOD STORES, INC.
- Site address
- 2020 N 17TH AVE.
- City
- FRANKLIN PARK
- State
- IL
- ZIP
- 60131
- Mailing
- 1955 W NORTH AVE., MELROSE PARK, IL 60131
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- SIC code (legacy)
- 4225
- Employees
- 960
- Ownership type
- A
Citations
23 citations on file for this inspection.
1910.119 D02 ID
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.119(d)(2)(i)(D): Process safety information pertaining to the technology of the process did not include the safe upper and lower limits for such items as temperatures, pressures, flows or compositions: a) Jewel Food Stores Inc. - The employer did not establish and document the safe upper and lower limits for the ammonia refrigeration processes ("North" and "South"), such as but not limited to: A. Liquid levels, pressures and temperatures in the high, low and constant pressure ammonia receivers. B. Ammonia compressor suction and discharge temperatures and pressures, and oil pressures. C. Evaporative condenser temperatures and pressures. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
1910.119 D02 IE
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Current $3,600
General-duty citation text
29 CFR 1910.119(d)(2)(i)(E): Process safety information pertaining to the technology of the process did not include an evaluation of the consequence of deviations, including those affecting the safety and health of employees: a) Jewel Food Stores Inc. - The employer did not evaluate and document the consequences of deviations from its ammonia refrigeration process technology ("North" and "South") for such operating parameters as, but not limited to: A. Temperatures, pressures and levels in the high, low and constant pressure ammonia receivers. B. Ammonia compressor suction and discharge pressures and temperatures, and oil pressures. C. Evaporative condenser temperatures and pressures. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (O) $3600.00
- — Z (S)
1910.119 D03 IB
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $6,500
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Process safety information pertaining to the equipment in the process did not include the piping and instrumentation diagrams (P&IDs): a) Jewel Food Stores Inc. - The employer's schematics of its ammonia refrigeration processes did not include information required for a Piping and Instrumentation Diagram (P&ID), as per recognized and generally accepted good engineering practice, as well as, the American National Standard Institude (ANSI), Instrument Society of America (ISA) ANSI/ISA S5.1 Code. Examples of information that was not included are, but are not limited to: A.Flow directions; B.Pump capacities and head pressures; C.Pressure vessel ratings, sizes, nozzle data and materials of construction; D.Computer control(s) and system input loops; E.Pipe sizes and materials of construction; F.Identification of and numbers for all valves. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S) $6500.00
- — Z (S) $5000.00
1910.119 D03 ID
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(d)(3)(i)(D): Process safety information pertaining to the equipment in the process did not include the relief system design and design bases: a) Jewel Food Stores Inc. - As part of its relief systems' designs ("North" and "South"), the employer did not determine and document the effects of built-up and superimposed header pressures on the relieving capacities of its individual pressure relief valves. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S)
- — Z (S)
1910.119 D03 IF
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(d)(3)(i)(F): Process safety information pertaining to the equipment did not include the design codes and standards employed: a) Jewel Food Stores Inc. - The employer did not have National Board of Boiler and Pressure Vessel Inspectors "U-1" forms (Manufacturers' Data Reports) to document the certified designs and ratings of its ammonia pressure vessels such as, but not limited to: VHS-001, VHS-002, VHS-003 and VHS-004, located in the "South" engine room. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstration that abatement is complete must be included with you certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — F (S)
- — Z (S)
1910.119 E03 I
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $3,600 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(i): The process hazard analysis did not address the hazards of the process: a) Jewel Food Stores Inc. - The employer's process hazard analyses ("North" and "South") did not address hazards of its ammonia refrigeration processes that were not controlled as prescribed by the ANSI/ASHRAE (American Society of heating, Refrigerating and Air Conditioning Engineers) Standard 15 "Safety Standard for Refrigeration Systems", or an equivalent. Such hazards included, but are not limited to: In the "North" and "South" refrigeration processes: A) The absence of visible and audible ammonia alarms inside the engine rooms, and outside each entrance to the engine rooms, with manual resets located inside the engine rooms and with the meaning of each alarm clearly marked by signage near the annunciators. B) The absence of legible permanent signs, securely attached and easily accessible, reading "Engine Room - Authorized Personnel Only" and further communicating that entry is forbidden except by those personnel trained in emergency procedures when the ammonia alarm has been activated. C) Door(s) communicating with the engine rooms were not tight fitting, permitting passage of escaping ammonia to other work areas of the building. D) Piping piercing the interior walls of the engine were not tightly sealed to the walls though which a passes permitting passage of escaping ammonia to other work areas. E) Emergency shutdown procedures including precautions to be observed in case of a breakdown or leak, not posted outside each engine room, immediately adjacent to each door. F) The absence of relieving devices to relieve hydrostatic pressure on portion(s) of liquid containing parts of the anhydrous ammonia system capable of being isolated from the system during operation, or service, that will be subjected to overpressure from hydrostatic expansion of the contained anhydrous ammonia liquid due to temperature rise. In addition, other hazards were not addressed, such as but not limited to: G) Engine room windows to the inside of other work areas were not blast resistant. I) Ammonia sensors, were mounted on high ceilings of both engine rooms ("North" and "South") that may not be able to detect releases of ammonia that form dense mixtures of ammonium hydroxide which tend to travel along the ground rather than rise rapidly. J) The inability to identify specifically which pressure relief valves(s) may have lifted during process operation. K) Emergency response drills not conducted. L) Emergency response spill exercises with the local Fire Department not conducted. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstration that abatement is complete must be included with you certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — F (O) $3600.00
- — Z (S) $5000.00
1910.119 E05
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $3,600 Reduced
General-duty citation text
29 CFR 1910.119(e)(5): The employer did not establish a system to promptly address the team's findings and recommendation; assure that the team's recommendations were resolved in a timely manner and that the resolution was documented; and actions were completed as soon as possible: a) Jewel Food Stores Inc. - The employer did not resolve and document in a timely manner its process hazard analysis (PHA) team's safety recommendations made in the 2/1999 process hazard analyses (PHA) recommendations made in the 2/1999 "South" process PHA as follows: A) "Consider installing an ammonia sensor in the RV discharge header with the alarm to the control room to alert engineers of the relief situation." B) "Consider coordinating emergency team's activities with all outside involved emergency response teams." C) "Verify the vessel's design can accommodate operating temperatures as low as negative 20 degrees Fahrenheit." b) Jewel Food Stores Inc. - The employer did not establish a system to complete actions recommended by the process hazard analysis (PHA) team as soon as possible. The employer approved, but did not complete, as soon as possible, actions recommended by its process hazard Analysis (PHA) team in the May, 2009, revalidations of the 1999 and 2003 PHAs of the "North" and "South" refrigeration processes, specifically: D)"The addition of chains or scaffolding to access valves located on top of tanks." ("North" process revalidation, May 2009) E)"The onsite haz mat refresher with the Franklin Park Fire Department." ("South" process revalidation, May 2009) In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstration that abatement is complete must be included with you certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — F (O) $3600.00
- — Z (S) $5000.00
1910.119 F01 IB
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $3,600 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(i)(B): The employer's written operating procedures covering the steps for each operating phase did not address normal operations: a) Jewel Food Stores Inc. - The employer's written "Normal Startup and Operating Procedures" (SOPs) for its refrigeration process compressors, including CPR-07 and CPR- 10, did not include the limits of operation for operating parameters, such as pressures (including oil pressures), temperatures, vessel levels and motor amps (under different seasonal designs). In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (O) $3600.00
- — Z (S) $5000.00
1910.119 F01 ID
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(f)(1)(i)(D): The employer's written operating procedures covering the steps for each operating phase did not address emergency shutdown including the conditions under which emergency shutdown is required, and the assignment of shutdown responsibility to qualified operators to ensure that emergency shutdown is executed in a safe and timely manner: a) Jewel Food Stores Inc. - The employer's written standard operating procedures (SOPs) for its refrigeration process compressors, including but not limited to CPR-07 and CPR-10, did not include the conditions under which emergency shutdown is necessary and the assignment of shutdown responsibility to qualified operators to ensure that emergency shutdown is executed in a safe and timely manner. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S)
- — Z (S)
1910.119 F01 II
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(f)(1)(ii): The employer's written operating procedures did not address the requirements for the operating limits listed in 29 CFR 1910.119(f)(1)(ii)(A) and (B): a) Jewel Food Stores Inc. - The employer's written procedures, such as but not limited to, "Operation of Ammonia Compressors", did not include the operating limits for, and deviations in operation parameters, such as compressor suction and discharge pressures and temperatures, crankcase and differential oil pressures, oil levels, noise and vibrations; and, did not describe the steps required to avoid deviations. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S)
- — Z (S)
1910.119 F01 IIIB
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Current $6,500
General-duty citation text
29 CFR 1910.119(f)(1)(iii)(B): The employer's written operating procedures covering safety and health considerations did not address the precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment: a) Jewel Food Stores Inc. - The employer's written "Line Break Procedure" (SOP #794-26) did not address the purging and evacuation of anhydrous ammonia as part of that procedure, including the precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S) $6500.00
- — Z (S)
1910.119 F01 IIIC
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(f)(1)(iii)(C): The employer's written operating procedures covering safety and health considerations did not address the control measures to be taken if physical contact or airborne exposure occurs: a) Jewel Food Stores Inc. - The employer's written operating procedures listed below did not include the control measure to be taken if employee exposure to anhydrous ammonia (physical or airborne) occurs. A) Line Break Procedure (SOP #795-26). B) Operations of Ammonia Compressors CPR-07 and CPR-10. C) Operation of Condensers CDW-04 and CDW-05. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S)
- — Z (S)
1910.119 F01 IV
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(f)(1)(iv): The employer's written operating procedures did not address requirements for the safety systems and their functions: a) Jewel Food Stores Inc. - The employer's written operating procedures, such as but not limited to, "Operation of Ammonia Compressors" and "Operation of Condensers" did not address the safety systems and their functions for computer software logic, interlocks, cutouts, pressure relief and detection systems and alarms. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S)
- — Z (S)
1910.119 F03
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(f)(3): The employer did not certify annually that the operating procedures were current and accurate: a) Jewel Food Stores Inc. - The employer did not ensure that the operating procedures for the ammonia refrigeration processes and equipment were annually certified by signature, including, but not limited to: A) "Operation of Ammonia Compressors" (CPR-07 and CPR-10). B) "Operation of Condensers" (evaporative condensers RFG-CDW-04 and RFG-CDW-05). C) "Unloading Anhydrous Ammonia Truck." D) "Operation of Ammonia Vessel (VS-11)." In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S)
- — Z (S)
1910.119 J02
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish and implement written procedures to maintain the on-going mechanical integrity of process equipment: a) Jewel Food Stores Inc. - The employer did not establish and implement written procedures to maintain the on-going integrity of its refrigeration equipment such, as but not limited to: A) Pressure Vessels, examples include but are not limited to, VHS-008, VHS-009, VHS-001 and VHS-002. B) Piping Systems. C) The refrigeration system controls and instrumentation. D) Ammonia Compressors, examples of which include but are not limited to, CPR-007, CPR- 008, CPR-001 and CPR-002. E) Evaporative Condensers, examples of which include but are not limited to, CDW-004, CDW- 005 and CDW-001. F) Evaporators, examples of which include but are not limited to, EVA-085, EVA-086, BRC- 001 and BRC-002. In accordance with 29 CFR 1904.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
1910.119 J04 I
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.119(j)(4)(i): Inspections and tests were not performed on processes equipment to maintain its mechanical integrity: a) Jewel Food Stores Inc. - The employer did not ensure that tests and inspections were conducted on the following equipment and components of the anhydrous ammonia systems, including: A) Compressor safety cutouts associated with ammonia compressors CPR-001 and CPR-002. B) Safety cutouts in the discharge headers of compressors for the ammonia refrigeration processes associated with the "North" and "South" engine rooms. C) Pressure relief valves for ammonia refrigeration processes associated with the "North" engine room. D) Evaporative condensers ("North" and "South"). In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
1910.119 J04 II
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $3,600 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity, did not follow recognized and generally accepted good engineering practices: a) Jewel Food Stores Inc. - The employer did not ensure that an independent inspection of ammonia vessels and heat exchangers, "North" and "South" processes, was carried out by a competent person independent of immediate commercial and production pressures for the installation; and, using whatever testing methods and extent that they would consider as necessary, to assure the on-going integrity of the equipment, as per the International Institute of Ammonia Refrigeration (IIAR) 110, or equivalent. A.) The employer replaced pressure relief valves associated with work orders (WO). WO 3471098 on 7/12/2008 and WO 3498359 on 7/25/2008 and did not document the conditions of the valves that were replaced, as per recognized and generally accepted good engineering practice. B.) The employer did not test the high and low pressure cutouts on the compressors in the "North" and "South" engine rooms, at the required setting(s), as prescribed by IIAR 110, or equivalent. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (O) $3600.00
- — Z (S) $5000.00
1910.119 J04 III
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment to maintain its mechanical integrity was not consistent with applicable manufacturers' recommendations and good engineering practices, or more frequently if determined to be necessary by prior operating experience: a) Jewel Food Stores Inc. - The employer's inspections and tests of critical equipment in its ammonia refrigeration processes ("North" and "South") were not conducted at a frequencies consistent with applicable manufacturers' recommendations and good engineering practices, equipment included, but was not limited to: A.) Ammonia compressors CPR-007, CPR-008 and CPR-009 for which vibration analyses have not been conducted since 2006. B.) Compressor safety cutouts associated with the ammonia compressors CPR-03, CPR-04 and CPR-05 were not function tested annually. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (O)
- — Z (S)
1910.119 J04 IV
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.119(j)(4)(iv): The employer did not document each inspection and test that had been performed on process equipment to maintain its mechanical integrity and did not identify the date of the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test, and the results of the inspection or test: a) Jewel Food Stores Inc. - The employer did not document the results and analyze for trends for the vibrations analyses conducted on ammonia compressors CPR -01 CPR-02 and CPR 03. b) Jewel Food Stores Inc. - The employer's "System Inspection Reports" including, but not limited to its CPR-009, CPR-010 and CPR-011 "Systems", did not have the dates on which these reports were generated, and did not have the name of the person who performed the inspections. c) The documented results of the inspection of an evaporative condenser conducted on 9/11/2008 did not identify the specific condenser for which the data had been obtained. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
1910.119 O04
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $6,500
General-duty citation text
29 CFR 1910.119(o)(4): The employer did not determine and document an appropriate response to each of the findings of the compliance audit required by 29 CFR 1910.119(o)(1), and document that the deficiencies had been corrected: a) Jewel Food Stores Inc. - The employer did not respond to the findings of the Process Safety Management program compliance audits of its ammonia refrigeration processes, and did not take and document corrective actions and their completion including the following: 11/2007 Audit: A) "Modify the Piping and Instrumentation Diagram (P&ID) to show the safety system interlocks, cutouts, detection and/or suppression systems." B) "Add controls loops to the P&ID. C) "Modify the written (Operating Procedure) program to describe the logic of the software and the relationship between the equipment and control system." D) "Create a standard operating procedure for evacuation and purging of the system (as part of the line breaking procedures.)" 10/2010 Audit: E) "Perform nondestructive testing for the vessels." F) "Develop written procedures to maintain the on-going integrity of a pressure vessels, storage tanks and piping systems." G) "Obtain all mill specifications sheets for process piping." In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (S) $6500.00
- — Z (S) $5000.00
1910.119 F01
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $25,000 · Current $25,000
General-duty citation text
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities in each covered process consistent with the process safety information and which addressed the elements listed in 29 CFR 1910.119(f)(1)(i) through (f)(1)(iv): a) Jewel Food Stores Inc. - The employer did not develop standard operating procedures (SOPs) to be used by employees for the testing of ammonia compressor safety cutouts for compressors, such as but not limited to CPR-07, CPR-08, CPR-09, CPR- 10 and CPR-11, and for replacement of solenoid control valves, such as on the hot gas lines to the evaporators, and others, for the "North" and "South" ammonia refrigeration processes. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). JEWEL FOOD STORES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THE OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1910.119(f)(1) WHICH WAS CONTAINED IN INSPECTION NUMBER 313848111 CITATION 1, ITEM 1 ISSUED ON 03/02/10 WITH RESPECT TO THE WORKSITE LOCATED AT 2020 N. 17th AVE. FRANKLIN PARK ILLINOIS, 60131. THE FINAL ORDER FOR INSPECTION NUMBER 313848111 WAS 01/03/11.
Recent events (2)
- — F (R) $25000.00
- — Z (R) $25000.00
1910.119 H02 VI
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(h)(2)(vi): The employer did not maintain a contract employee injury and illness log related to the contractor's work in the process areas. a) Jewel Food Stores Inc. - The employer did not maintain a contract employee injury and illness log related to the work of outside contractors, such as DualTemp and Spur Electric, in its covered processes. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — F (O)
- — Z (O)
1910.119 N
- Issued
- Jul 8, 2011
- Abate by
- Oct 5, 2011
General-duty citation text
29 CFR 1910.119(n): The employer's emergency action plan did not include procedures for handling small releases: a) Jewel Food Stores Inc. - The employer did not develop and establish procedures to be followed by employees that identified the necessary level of knowledge needed for employees to distinguish between releases, and spills that can be handled by employee(s) not trained to handle release(s) requiring an emergency response, and did not address training needs, specify personal protective equipment and air monitoring devices to be used, and describe any spill control procedures to be followed. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstration that abatement is complete must be included with you certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — F (O)
- — Z (O)
More inspections at Jewel Food Stores, INC.
View Jewel Food Stores, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315180745.