CANTON, GA ·
OSHA Inspection: GO PLASTICS LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GO PLASTICS LLC in 515 BROWN INDUSTRIAL PARKWAY, CANTON, GA 30114 (NAICS 337215). OSHA activity number 315737916.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GO PLASTICS LLC
- Site address
- 515 BROWN INDUSTRIAL PARKWAY
- City
- CANTON
- State
- GA
- ZIP
- 30114
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337215
- SIC code (legacy)
- 3089
- Employees
- 66
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 9, 2012
- Abate by
- Mar 23, 2012
- Penalty
- Initial $2,975 · Current $2,500 Reduced
M102
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm including severe burns to employees, in that employees were exposed to dust explosion, deflagration, or other fire hazards from the dust collection system: Manufacturing Building - In the back of the production area, next to the pulverizer,where the dust collector was located, employees working in the area were exposed to explosion, deflagration, or fire hazards due the lack of isolation devices, on or about 8/12/11. Among other methods, a feasible abatement method to correct this hazard is to follow the NFPA 654 Standard for The Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulates Solids, paragraph 7.1.4.1 and 7.1.5.1, which require isolation devices to be provided to prevent deflagration propagation between pieces of equipment connected by ductwork and from air-material separators (dust collectors) upstream to the work area. Isolation devices include but are not limited to chokes, rotary valves, and flame front diverters. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
- · P (S) $2500.00
- · I (S) $2500.00
- · Z (S) $2975.00
1910.22 A01
- Issued
- Jan 9, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $2,975 · Current $1,000 Reduced
M102
Recent events (2)
- · I (S) $1000.00
- · Z (S) $2975.00
1910.95 K01
- Issued
- Jan 9, 2012
- Abate by
- Feb 23, 2012
- Penalty
- Initial $1,785 · Current $500 Reduced
Recent events (2)
- · I (O) $500.00
- · Z (S) $1785.00
1910.1200 F05
- Issued
- Jan 9, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $1,785 · Current $1,200 Reduced
Recent events (2)
- · I (S) $1200.00
- · Z (S) $1785.00
1910.1200 H01
- Issued
- Jan 9, 2012
- Abate by
- Feb 2, 2012
1910.134 C02 I
- Issued
- Jan 9, 2012
- Abate by
- Feb 2, 2012
1910.134 C02 II
- Issued
- Jan 9, 2012
- Abate by
- Feb 2, 2012
More inspections at GO Plastics LLC
View GO Plastics LLC's full OSHA safety record →
More inspections in this industry (NAICS 337215)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 315737916.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.