CISCO, TX ·
OSHA Inspection: QUAIL WELL SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QUAIL WELL SERVICE in & OR ABOUT 250 HIGHWAY 206, CISCO, TX 76437 (NAICS 213111). OSHA activity number 316044809.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUAIL WELL SERVICE
- Site address
- & OR ABOUT 250 HIGHWAY 206
- City
- CISCO
- State
- TX
- ZIP
- 76437
- Mailing
- 110 CADDO, ABILENE, TX 79602
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 4
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- May 23, 2012
- Abate by
- May 29, 2012
- Penalty
- Initial $4,200 · Current $4,200
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees working from elevated heights of oil-well service rig derrick. On or about January 17, 2012 and times prior to, at Reaner #1, an employee worked from the tubing board where an emergency escape device was not installed and available for use. The employee working from the tubing board was exposed to a potential fall or severe burns associated with, and in the event of a fire or explosion at the oil-well service rig platform. One feasible and acceptable abatement method to correct this hazard would be to ensure that an auxiliary means of escape is installed and ready for use prior to personnel working in the derrick in accordance with Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations API 54, Third Edition, August 1999, Section 6.10.1, Auxiliary Escape: "On all land rigs, the derrick or mast shall have an auxiliary means of escape installed prior to personnel working in the derrick.
1910.23 D01
- Issued
- May 23, 2012
- Abate by
- Jun 4, 2012
- Penalty
- Initial $1,800 · Current $1,800
1910.219 C03
- Issued
- May 23, 2012
- Abate by
- Jun 4, 2012
- Penalty
- Initial $4,200 · Current $4,200
1910.219 D01
- Issued
- May 23, 2012
- Abate by
- Jun 4, 2012
- Penalty
- Initial $4,200 · Current $4,200
More inspections at Quail Well Service
View Quail Well Service's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 316044809.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.