OSHA Inspection: WESTERN ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WESTERN ROOFING, INC. in 15715 IDAHO CENTER BLVD, NAMPA, ID 83651 (NAICS 238160). OSHA activity number 330017914.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Western Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Western Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15715 IDAHO CENTER BLVD
City
NAMPA
State
ID
ZIP
83651
Mailing
2609 KEIM LN, NAMPA, ID 83687
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 7, 2011
Abate by
Apr 28, 2011
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were used by employees did not have approved ground fault circuit interrupters for personnel protection:        a) Jobsite: On March23 2011, and times prior thereto, employees were using 120 volt generator power from a unit > 5 KW,  where there was no assured grounding program in place or GFCIs for electric portable hand-held heat guns.     Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $765
  • — Z (S) $1530

1926.502 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 7, 2011
Penalty
Initial $1,300 · Current $650 Reduced
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:    a)  Jobsite:  On March 23 2011, and times prior thereto,  employees were working on the West side of a low slope roof near the edge where the wire rope guard rail was loose and allowed to droop excessively to approximately 35 inches above the walking/working surfaces.        Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $650
  • — Z (S) $1300

1926.502 B01

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Apr 7, 2011
Abate by
Apr 14, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:    a)  Jobsite:  On March 23 2011, and times prior thereto,  employees were working on the West side of a low slope roof near the edge where the wire rope guard rail was loose and allowed to droop excessively to approximately 35 inches above the walking/working surfaces.        Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 B09

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 7, 2011
Abate by
Apr 14, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(9): The employer failed to ensure that wire rope used as a top rail was flagged at 6-foot intervals with high-visibility material:                                                                                                      	                              a)  West Section of Roof: On March 23, 2011, and times prior thereto, employees were on a roof that had a wire rope guard rail that did not have any flagging.      Note:  Abatement certification is required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A02 III

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Apr 7, 2011
Abate by
Apr 28, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used.    a)  Jobsite:  On March 23, 2011 and times prior thereto, employees were not adequately trained to etablish a new fall protection system, in that they did not know the requirement to establish an interim fall protection system when they removed the existing guard rail system from the parapet wall while they installed the final section of roofing over the parapet wall and cap.        Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.28 A

Other-than-serious 1 instance 1 exposed
Issued
Apr 7, 2011
Abate by
Apr 28, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions:    a)  Jobsite:  On March 23, 2011 and times prior thereto, employees were using Johns Manville TPO membrane cleaner on a rubber roofing material without impervious gloves as recommended by the manufacturer's  MSDS.      Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.152 F03

Deleted Other-than-serious 1 instance 1 exposed
Issued
Apr 7, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.152(f)(3): Flammable liquids were used where there were open flames or other sources of ignition within 50 feet of the operation:    a)  Jobsite:  On March 23, 2011 and times prior thereto, employees placed a 5 gallon container of a flammable liquid, Johns Manville TPO membrane cleaner, with the cap off on top of a running gas fired electric generator.    Note: Abatement certification is required for this item.