Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNRISE MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUNRISE MASONRY, INC. in 3509 XANTHIA CT, DENVER, CO 80238 (NAICS 238140). OSHA activity number 330630666.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunrise Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for Sunrise Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3509 XANTHIA CT
City
DENVER
State
CO
ZIP
80238
Mailing
8151 QUAIL RUN RD, WATKINS, CO 80137
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.451 G01

Serious Gravity 5 2 instances 4 exposed
Issued
Jun 20, 2011
Abate by
Jul 19, 2011
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1926.451(g)(1):  Each employee on a scaffold 10 feet above a lower level was not protected from falling to the lower level:    (a)  Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238:  On and before June 4, 2011, the exposing employer did not ensure that employees were protected from a fall from elevation, in that guardrails or other suitable fall protection were not properly installed on the working platforms of the scaffolding. The scaffold used at the front entrance of the residential home lacked midrails and endrails on both the 2nd and 3rd levels of the scaffold. Employees worked from the 2nd and 3rd levels at the project site. This condition exposed employees to falls of approximately 16 feet.    (b)  Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238:  On and before June 4, 2011, the exposing employer did not ensure that employees were protected from a fall from elevation, in that guardrails or other suitable fall protection were not properly installed on the working platforms of the scaffolding. Employees walked on planking that connected two separate scaffold sections. Toprails, and midrails were not installed at this location on the scaffold. This condition exposed employees to a fall of 16 feet to the ground below.
Recent events (2)
  • — I (S) $1224
  • — Z (S) $2040

1926.451 C02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 20, 2011
Abate by
Jul 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2)(i):  Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement:     (a)  Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238:  On and before June 4, 2011, the exposing employer did not ensure the footings of the fabricated scaffold were secured to prevent displacement. Footings were placed on top of wood mud sills; however, the footings were not secured to the mud sills. Several footings had shifted and were slipping off the mud sills, thus adding instability to the scaffold. This condition exposed employees to falls approximately 16 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 20, 2011
Abate by
Jul 11, 2011
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1926.454(a):  The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedure(s) to control or minimize those hazards:    (a)  Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238:  On and before June 4, 2011, the exposing employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedure(s) to control or minimize those hazards. Employees worked from the 2nd and 3rd levels at the project site. This condition exposed the employees to a fall of approximately 16 feet due to recognizing the hazards of working on the scaffold.    Abatement Note: The training shall include the following elements at a minimum:    (1)  The nature of any electrical hazards, fall hazards, and falling object hazards in the work area;    (2)  The correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection systems and falling object protection systems being used:    (3)  The proper use of the scaffold, and the proper handling of materials on the scaffold;    (4)  The maximum intended load and the load-carrying capacities of the scaffold used; and    (5)  Any other pertinent requirements of this subpart.
Recent events (2)
  • — I (S) $1224
  • — Z (S) $2040

1926.454 B

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 20, 2011
Abate by
Jul 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.454(b): Employees involved in erecting, disassembling, moving, operating, repairing, maintaining or inspecting a scaffold were not trained by a competent person to recognize any hazards associated with the scaffold in question:    (a)  Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238:  On and before June 4, 2011, the exposing employer did not ensure employees were provided with adequate training concerning erecting, disassembling, moving, operating, repairing, maintaining or inspecting a scaffold. This condition exposed employees to falls of approximately 16 feet.    Abatement Note: The training shall include the following elements at a minimum:    (1)  The nature of any electrical hazards, fall hazards, and falling object hazards in the work area;    (2)  The correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection systems and falling object protection systems being used:    (3)  The proper use of the scaffold, and the proper handling of materials on the scaffold;    (4)  The maximum intended load and the load-carrying capacities of the scaffold used; and    (5)  Any other pertinent requirements of this subpart.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Sunrise Masonry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330630666.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.