DENVER, CO —
OSHA Inspection: SUNRISE MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUNRISE MASONRY, INC. in 3509 XANTHIA CT, DENVER, CO 80238 (NAICS 238140). OSHA activity number 330630666.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUNRISE MASONRY, INC.
- Site address
- 3509 XANTHIA CT
- City
- DENVER
- State
- CO
- ZIP
- 80238
- Mailing
- 8151 QUAIL RUN RD, WATKINS, CO 80137
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 G01
- Issued
- Jun 20, 2011
- Abate by
- Jul 19, 2011
- Penalty
- Initial $2,040 · Current $1,224 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold 10 feet above a lower level was not protected from falling to the lower level: (a) Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238: On and before June 4, 2011, the exposing employer did not ensure that employees were protected from a fall from elevation, in that guardrails or other suitable fall protection were not properly installed on the working platforms of the scaffolding. The scaffold used at the front entrance of the residential home lacked midrails and endrails on both the 2nd and 3rd levels of the scaffold. Employees worked from the 2nd and 3rd levels at the project site. This condition exposed employees to falls of approximately 16 feet. (b) Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238: On and before June 4, 2011, the exposing employer did not ensure that employees were protected from a fall from elevation, in that guardrails or other suitable fall protection were not properly installed on the working platforms of the scaffolding. Employees walked on planking that connected two separate scaffold sections. Toprails, and midrails were not installed at this location on the scaffold. This condition exposed employees to a fall of 16 feet to the ground below.
Recent events (2)
- — I (S) $1224
- — Z (S) $2040
1926.451 C02 I
- Issued
- Jun 20, 2011
- Abate by
- Jul 11, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: (a) Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238: On and before June 4, 2011, the exposing employer did not ensure the footings of the fabricated scaffold were secured to prevent displacement. Footings were placed on top of wood mud sills; however, the footings were not secured to the mud sills. Several footings had shifted and were slipping off the mud sills, thus adding instability to the scaffold. This condition exposed employees to falls approximately 16 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 A
- Issued
- Jun 20, 2011
- Abate by
- Jul 11, 2011
- Penalty
- Initial $2,040 · Current $1,224 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedure(s) to control or minimize those hazards: (a) Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238: On and before June 4, 2011, the exposing employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedure(s) to control or minimize those hazards. Employees worked from the 2nd and 3rd levels at the project site. This condition exposed the employees to a fall of approximately 16 feet due to recognizing the hazards of working on the scaffold. Abatement Note: The training shall include the following elements at a minimum: (1) The nature of any electrical hazards, fall hazards, and falling object hazards in the work area; (2) The correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection systems and falling object protection systems being used: (3) The proper use of the scaffold, and the proper handling of materials on the scaffold; (4) The maximum intended load and the load-carrying capacities of the scaffold used; and (5) Any other pertinent requirements of this subpart.
Recent events (2)
- — I (S) $1224
- — Z (S) $2040
1926.454 B
- Issued
- Jun 20, 2011
- Abate by
- Jul 11, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(b): Employees involved in erecting, disassembling, moving, operating, repairing, maintaining or inspecting a scaffold were not trained by a competent person to recognize any hazards associated with the scaffold in question: (a) Sunrise Masonry, Inc. at 3509 Xanthia Ct in Denver, CO 80238: On and before June 4, 2011, the exposing employer did not ensure employees were provided with adequate training concerning erecting, disassembling, moving, operating, repairing, maintaining or inspecting a scaffold. This condition exposed employees to falls of approximately 16 feet. Abatement Note: The training shall include the following elements at a minimum: (1) The nature of any electrical hazards, fall hazards, and falling object hazards in the work area; (2) The correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection systems and falling object protection systems being used: (3) The proper use of the scaffold, and the proper handling of materials on the scaffold; (4) The maximum intended load and the load-carrying capacities of the scaffold used; and (5) Any other pertinent requirements of this subpart.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Sunrise Masonry, INC.
View Sunrise Masonry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330630666.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.