COSHOCTON, OH ·
OSHA Inspection: COSHOCTON GRAIN COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COSHOCTON GRAIN COMPANY in 475 BROWNS LANE, COSHOCTON, OH 43812 (NAICS 424510). OSHA activity number 330631094.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COSHOCTON GRAIN COMPANY
- Site address
- 475 BROWNS LANE
- City
- COSHOCTON
- State
- OH
- ZIP
- 43812
- Mailing
- P. O. BOX 606, COSHOCTON, OH 43812
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 10
- Ownership type
- Private (A)
Citations
17 citations on file for this inspection.
1910.23 A02
- Issued
- Jul 28, 2011
- Abate by
- Aug 11, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.23(a)(2): Every ladderway floor opening or platform shall be guarded by a standard railing with standardtoeboard on all exposed sides (except at entrance to opening), with the passage through the railing either provided with a swinging gate or so offsetthat a person cannot walk directly into the opening: a. In the small dump room, there was a hole to a ladder way opening where employees could enter the basement which was not properly guarded from employees accidently falling into the hole there by exposing employees to a seven foot fall hazard.
Recent events (2)
- · I (S) $1020
- · Z (S) $2040
1910.23 C01
- Issued
- Jul 28, 2011
- Abate by
- Aug 17, 2011
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides, a. On the top of block dust house system where employees perform maintenance, clean the dust collector, and check temperature of the grain, the employer did not provide a means of fall protection thereby exposing employees to an 8 foot fall hazard. b. On the fourth level of the Old House where doors are opened to load or unload materials, the employer failed to install fall protection such as, but not limited to a guardrail system thereby exposing employees to a 100 foot fall hazard. c. On the third level of the Old House where doors are opened to load or unload materials, the employer failed to install fall protection such as, but not limited to a guardrail system thereby exposing employees to a 70 foot fall hazard. d. On the second level of the Old House where doors are opened to load and unload materials, the employer failed to install a fall protection system such as, but not limited to a guardrail system thereby exposing employees to a 50 foot fall hazard. e. On the first level of the Old House where doors are opened to load and unload materials, the employer failed to install a fall protection system such as, but not limited to a guardrail system thereby exposing employees to a 30 foot fall hazard.
Recent events (2)
- · I (S) $1275
- · Z (S) $2550
1910.23 E01
- Issued
- Jul 28, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $1,530 · Current $765 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): A standard railing shall consist of top rail, intermediate rail, and posts, and shall have avertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfacedthroughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, orramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard: a. In the old house power room where employees entered and exited the basement, the employer did not provide a midrail form the stairway thereby exposing employees to a fall hazard. b. In the main control room where employees gained access to the basement, the stairs were not equipped with a midrail. c. On the warehouse dock where employees walked to load and unload trucks, the employer did not install midrail thereby exposing employees to a fall hazard. d. In the mezzanine stairway from the ground to the basement, the employer failed to install midrail thereby exposing employees to a trip/fall hazard. e. In the small dump room where employees entered the basement from a ladder way, the employer did not install a midrail.
Recent events (2)
- · I (S) $765
- · Z (S) $1530
1910.147 C05 II D
- Issued
- Jul 28, 2011
- Abate by
- Aug 12, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices shall indicate the identity of the employee applying the device(s): a.In the entrance to A House, the lock out/tag out device was not marked with the identity of the employee who applied the tag thereby exposing employees to a contact hazard. b. In the small dump control room where electrical equipment is operated, there were several tag out devices which were attached to machines which were not identified as to who applied the tag thereby exposing employees to a contact hazard. c.In the main control room, where electrical equipment was operated, the tag out devices were not identified as to the operator who applied the tag out device thereby exposing employees to a contact hazard.
Recent events (2)
- · I (S) $1020
- · Z (S) $2040
1910.178 L01 I
- Issued
- Jul 28, 2011
- Abate by
- Aug 29, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. On the site where employees operated a Bobcat Steer loader to move grain and other materials around, the employer did not provide operator training before allowing the employees to operate the equipment thereby exposing employees to a struck-by hazard.
Recent events (2)
- · I (S) $1020
- · Z (S) $2040
1910.178 L04 III
- Issued
- Jul 28, 2011
- Abate by
- Aug 27, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years: a. On the Coshocton site where employees operated a Bob Cat skid steer, the employees were not provided a refresher training every three years thereby exposing employees to a struck-by hazard. The employee who had received training in 2005 had not been provided refresher training on the skid loader which was operated on the site.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A05
- Issued
- Jul 28, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch: a. In the small dump control area, there was a Q Mark fan which was located on the floor which was not properly guarded thereby exposing employees to a contact hazard.
Recent events (2)
- · I (S) $1020
- · Z (S) $2040
1910.219 C02
- Issued
- Jul 28, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.219(c)(2): Guarding horizontal shafting. a. In the basement of 215 fan room, the horizontal shafting which was part of the powering of the aeriation fans was not guarded thereby exposing employees to a caught-in hazard. b. In the basement of the control room, the horizontal shafting to the dumper belt had a 7 inch opening to the shaft thereby exposing employees to a caught-in hazard.
Recent events (2)
- · I (S) $1020
- · Z (S) $2040
1910.219 C04 I
- Issued
- Jul 28, 2011
- Abate by
- Aug 12, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves: a. In the new bin area, the shafts protruded from the ends of shafts thereby exposing employees to a contact hazard. b. In the new bin area, the shaft on the end of the jump conveyor protruded 1 1/2 inches out from the end of the shaft thereby exposing employees to a contact hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 H01
- Issued
- Jul 28, 2011
- Abate by
- Aug 12, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(h)(1): All projecting keys, setscrews, and other projections in revolving parts shall be removed or made flush or guarded by metal cover. This subparagraph does not apply to keys or setscrews within gear or sprocket casings or other enclosures, nor tokeys, setscrews, or oilcups in hubs of pulleys less than twenty (20) inches in diameter where they are within the plane of the rim of thepulley: a. In the new bin area where the ends of shafts had bolts extending out from the end of the shaft thereby exposing employees to a contact hazard. b. In the new bin area, the shaft on the end of the jump conveyor was extended 1 1/2 inches out from the end of the shaft thereby exposing employees to a contact hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 D01
- Issued
- Jul 28, 2011
- Abate by
- Aug 12, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform,shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punchpresses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may beguarded with a disk covering the spokes: a. In the new bin area beside bin 403, there was no protection such as a guard to the rear of the belt and pulley thereby exposing employees to a caught-in hazard. b. In the new bin area beside the dryer augers, there was no protection such as a guard behind the rear of the auger thereby exposing employees to a caught-in hazard.
Recent events (2)
- · I (S) $1020
- · Z (S) $2040
1910.303 F01
- Issued
- Jul 28, 2011
- Abate by
- Aug 29, 2011
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.303(f)(1): Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident: a. In the new bin area where grain and soy beans were stored in bins, the disconnects for the blower motors were not marked as to the equipment they operated thereby exposing employees to a contact hazard. b. In the Small Dump room where motors and disconnects are in operation, the disconnects were not marked as to the equipment it operated thereby exposing employees to a contact hazard.
Recent events (2)
- · I (S) $1275
- · Z (S) $2550
1910.305 A02 X
- Issued
- Jul 28, 2011
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: a. At the doorway to the dust system power room, the employer ran a 480 volt electrical cord underneath the door to the powder room for use as temporary power pinching the energized electrical wire thereby exposing employees to a contact hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $2550
1910.305 B01 II
- Issued
- Jul 28, 2011
- Abate by
- Aug 29, 2011
- Penalty
- Initial $0 · Current $1,275
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed: a. In the new bin area beside bin 403, there was an unused opening on the bottom and side of the disconnect thereby exposing employees to a contact hazard. b. In the small dump control area; there was a missing circuit breaker on a energized electrical panel thereby exposing employees to a contact hazard. c. In the small dump control area, the electrical panel used to control motors and equipment had an unused opening in the energized electrical control panel thereby exposing employees to a contact hazard. d. In the load out room where grain is transferred in the event of a problem, there was an unused opening in the bottom of the energized electrical panel thereby exposing employees to contact hazard.
Recent events (2)
- · I (S) $1275
- · Z (S) $0
1910.305 E01
- Issued
- Jul 28, 2011
- Abate by
- Aug 12, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water from entering and accumulating within the enclosures and shall be mounted so there is at least 6.35-mm (0.25-in.) airspace between the enclosure and the wall or other supporting surface. However, nonmetallic enclosures may be installed without the airspace on a concrete, masonry, tile, or similar surface. The enclosures shall be weatherproof in wet locations: a. In the new bin area where electrical cabinet boxes were installed in the outside area, the backs of the electrical boxes had holes to allow water to accumulate in the electrical boxes thereby exposing employees to a contact hazard.
Recent events (2)
- · I (S) $1020
- · Z (S) $2040
1910.305 G01 IV A
- Issued
- Jul 28, 2011
- Abate by
- Aug 4, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Temporary wiring shall not be used: As a substitute for the fixed wiring of a structure; a. In the basement of the main grain transfer building where grain in transfered amoung bins and loaded onto rail cars for shipment to other states, there was an extension cord connected to a sump pump which was used as temporary wiring thereby exposing employees to a contact hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.335 B01
- Issued
- Jul 28, 2011
- Abate by
- Aug 29, 2011
- Penalty
- Initial $1,530 · Current $765 Reduced
General-duty citation text
29 CFR 1910.335(b)(1): Safety signs, safety symbols, or accident prevention tags shall be used where necessary to warn employees about electrical hazards which may endanger them, as required by 1910.145: a. In the grain facility where employees work around energized electrical equipment such as, but not limited to, disconnects, electrical panels, the employer did not post arc flash warning to warm employees of potential hazards thereby exposing employees to a fire/explosion hazard.
Recent events (2)
- · I (S) $765
- · Z (S) $1530
More inspections at Coshocton Grain Company
View Coshocton Grain Company's full OSHA safety record →
More inspections in this industry (NAICS 424510)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330631094.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.