FRANKLIN PARK, IL —
OSHA Inspection: ARLINGTON METALS CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ARLINGTON METALS CORPORATION in 11355 FRANKLIN AVENUE, FRANKLIN PARK, IL 60131 (NAICS 331419). OSHA activity number 330774472.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARLINGTON METALS CORPORATION
- Site address
- 11355 FRANKLIN AVENUE
- City
- FRANKLIN PARK
- State
- IL
- ZIP
- 60131
- Mailing
- 11355 FRANKLIN AVENUE, FRANKLIN PARK, IL 60131
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331419
- Employees
- 60
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.178 L01 I
- Issued
- Sep 15, 2011
- Abate by
- Oct 14, 2011
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). a) The employer did not conduct any training nor evaluation for employees that occasionally operate the forklift.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.179 G01 V
- Issued
- Sep 15, 2011
- Abate by
- Oct 14, 2011
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not constructed to prevent electrical shock and were not clearly marked for identification of functions. a) Bay #1 - overhead crane had its pendant control box with the protective casing taped up holding it together exposing energized electrical wires. b) Bay #4 - The Harnischfeger P&H 30 ton crane, serial #CI - 28653, had its pendant control box with the protective sheath detached exposing energized wires, the buttons on the pendant control box were not clearly marked to verify their functions, and the protective casing on the pendant control box was cracked at the top exposing energized electrical wires. c) Bay #6 - The Harnischfeger P&H 30 ton crane, serial #CI - 28687, had its pendant control box with the protective sheath detached exposing energized wires, the buttons on the pendant control box were not clearly marked to verify their functions, and the protective casing on the pendant control box was cracked at the top exposing energized electrical wires.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.213 H01
- Issued
- Sep 15, 2011
- Abate by
- Oct 14, 2011
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut: a) Pallet Area - The Delta Radial Arm Saw lower portion(s) of the blade were not guarded to the full diameter of the saw blade by a device that automatically adjusts itself to the thickness of the stock and remained in contact with the material being cut.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.305 A02 X
- Issued
- Sep 15, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. a) Bay #1 Pallet Assembly Area - The flexible electrical cord used on the Milwaukee portable circular saw ran across the floor where employees walk through the area and subject it to damage.
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1904.29 B01
- Issued
- Sep 15, 2011
- Abate by
- Sep 29, 2011
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1904.29(b)(1): A log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent). was not completed in the detail as required by the regulatin. a) The employer for the calendar years 2007, 2008, and 2009, did not total the OSHA 300 entry logs the OSHA 300(A) summary sheet.
Recent events (2)
- — I (O) $1249.5
- — Z (O) $1785
1910.141 A03 I
- Issued
- Sep 15, 2011
- Abate by
- Sep 26, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allows: a) Lunch Room - The employer did not maintain the refrigerator in a clean and sanitary condition. b) Lunch Room - The employer did not maintain the microwave oven in a clean and sanitary condition.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Sep 15, 2011
- Abate by
- Sep 26, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. a) Lunch Room - The Menumaster microwave oven had an electrical cord with the protective sheath detached from the end, exposing energized wires. b) Pallet Area - The Milwaukee circular saw had an electrical cord with the protective sheath detached from the end, exposing energized wires.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.334 A02 I
- Issued
- Sep 15, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated. a) Bay #1 - The employer did not visually inspect the flexible cord on the Delta radial arm saw, the cord had its outer jacket damaged exposing electrical wires.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Arlington Metals Corporation
View Arlington Metals Corporation's full OSHA safety record →
More inspections in this industry (NAICS 331419)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330774472.