Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARLINGTON METALS CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ARLINGTON METALS CORPORATION in 11355 FRANKLIN AVENUE, FRANKLIN PARK, IL 60131 (NAICS 331419). OSHA activity number 330774472.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arlington Metals Corporation — free Get an email when a new federal OSHA severe-injury report for Arlington Metals Corporation is published. One employer, no account, unsubscribe in one click.
Site address
11355 FRANKLIN AVENUE
City
FRANKLIN PARK
State
IL
ZIP
60131
Mailing
11355 FRANKLIN AVENUE, FRANKLIN PARK, IL 60131
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331419
Employees
60
Ownership type
A

8 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 2 instances 1 exposed
Issued
Sep 15, 2011
Abate by
Oct 14, 2011
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    a) The employer did not conduct any training nor evaluation for employees that occasionally operate the forklift.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.179 G01 V

Serious Gravity 5 3 instances 1 exposed
Issued
Sep 15, 2011
Abate by
Oct 14, 2011
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not constructed to prevent electrical shock and were not clearly marked for identification of functions.    a) Bay #1 - overhead crane had its pendant control box with the protective casing taped up holding it together exposing energized electrical wires.       b) Bay #4 - The Harnischfeger P&H 30 ton crane, serial #CI - 28653, had its pendant control box with the protective sheath detached exposing energized wires, the buttons on the pendant control box were not clearly marked to verify their functions, and the protective casing on the pendant control box was cracked at the top exposing energized electrical wires.      c) Bay #6 - The Harnischfeger P&H 30 ton crane, serial #CI - 28687, had its pendant control box with the protective sheath detached exposing energized wires, the buttons on the pendant control box were not clearly marked to verify their functions, and the protective casing on the pendant control box was cracked at the top exposing energized electrical wires.
Recent events (2)
  • — I (S) $1666
  • — Z (S) $2380

1910.213 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 15, 2011
Abate by
Oct 14, 2011
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut:    a) Pallet Area  - The Delta Radial Arm Saw lower portion(s) of the blade were not guarded to the full diameter of the saw blade by a device that automatically adjusts itself to the thickness of the stock and remained in contact with the material being cut.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.305 A02 X

Serious Gravity 1 2 instances 1 exposed
Issued
Sep 15, 2011
Abate by
Oct 5, 2011
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.    a) Bay #1 Pallet Assembly Area - The flexible electrical cord used on the Milwaukee portable circular saw ran across the floor where employees walk through the area and subject it to damage.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1904.29 B01

Other-than-serious 3 instances 1 exposed
Issued
Sep 15, 2011
Abate by
Sep 29, 2011
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1904.29(b)(1): A log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent). was not completed in the detail as required by the regulatin.      a) The employer for the calendar years 2007, 2008, and 2009, did not total the OSHA 300 entry logs the OSHA 300(A) summary sheet.
Recent events (2)
  • — I (O) $1249.5
  • — Z (O) $1785

1910.141 A03 I

Other-than-serious 2 instances 1 exposed
Issued
Sep 15, 2011
Abate by
Sep 26, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allows:    a) Lunch Room - The employer did not maintain the refrigerator in a clean and sanitary condition.      b) Lunch Room - The employer did not maintain the microwave oven in a clean and sanitary condition.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 2 instances 1 exposed
Issued
Sep 15, 2011
Abate by
Sep 26, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.    a) Lunch Room - The Menumaster microwave oven had an electrical cord with the protective sheath detached from the end, exposing energized wires.     b) Pallet Area - The Milwaukee circular saw had an electrical cord with the protective sheath detached from the end, exposing energized wires.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 I

Other-than-serious 1 instance 1 exposed
Issued
Sep 15, 2011
Abate by
Oct 5, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.      a) Bay #1 - The employer did not visually inspect the flexible cord on the Delta radial arm saw, the cord had its outer jacket damaged exposing electrical wires.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Arlington Metals Corporation's full OSHA safety record →