Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FAST FRAMING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FAST FRAMING INC. in 3452 NORTH CENTRAL PARK BLVD., DENVER, CO 80238 (NAICS 238130). OSHA activity number 330921206.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fast Framing INC. — free Get an email when a new federal OSHA severe-injury report for Fast Framing INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FAST FRAMING INC.
Site address
3452 NORTH CENTRAL PARK BLVD.
City
DENVER
State
CO
ZIP
80238
Mailing
2132 SOUTH QUENTIN WAY UNIT 101, AURORA, CO 80014
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 5 26 instances 6 exposed
Issued
Jul 12, 2011
Abate by
Jul 27, 2011
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:         a)  Fast Framing Inc. at 3452 North Central Park Blvd., Denver, CO 80238:  On or before 7/9/11, the employer did not ensure that employees were protected from falling when framing this 5 unit complex in the following instances:         1)  Each of the five units had a stairway hole on the second floor that not covered or guarded, and the employees were not tied off.  The fall hazard was 21'6"  to the basement;         2)  One stairway hole on the main floor was missing endrails, with a fall hazard of 10'2" to the basement, and the employees were not tied off;         3)  Each of the 5 units had three windows openings measuring 36" above the second floor, with the openings measuring from 3' to 6' wide, and each opening was not guarded, and the employees were not tied off, with exterior fall hazards of about 11';         4)  The employees were working within 6 feet of the edge of the second floor, on multiple units, without fall protection, with fall hazards of about 11'.    Conditions exposed employees to fall hazards of up to 21'6".    Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").    Abatement note:  Interior holes greater than 12" wide that the employees could step into need to be guarded by horizontal guardrails if the studs are more than 19" apart.  This rule (1926.502(b)(2)(iii)) applies to guarding interior holes, but not to exterior walls.    Abatement note;  The window openings need to be guarded if the lower ledge is less than 39" high from the floor (1926.502(b)(1).
Recent events (2)
  • — I (S) $1224
  • — Z (S) $2040

View Fast Framing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330921206.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.