Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FAST FRAMING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FAST FRAMING INC. in 8581 EAST 21ST AVENUE, DENVER, CO 80238 (NAICS 238130). OSHA activity number 330967944.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fast Framing INC. — free Get an email when a new federal OSHA severe-injury report for Fast Framing INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FAST FRAMING INC.
Site address
8581 EAST 21ST AVENUE
City
DENVER
State
CO
ZIP
80238
Mailing
2132 SOUTH QUENTIN WAY UNIT 101, AURORA, CO 80014
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.404 F06

Other-than-serious 1 instance 3 exposed
Issued
Aug 3, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a)  Fast Framing Inc. at 8581 East 21st Avenue, Denver, CO 80238:  On or before 7/30/11, the employer allowed employees to use a yellow electrical cord that was not grounded. The cord was used to power a Mag 77 Skilsaw, and a Rolair air compressor model 6820K170001, serial number 10010791.  Both tools were not double insulated.  The cord was plugged into a temporary panel with a ground fault circuit interrupter (GFCI).  Condition exposed employees to electrical shock hazards.    Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (1)
  • — Z (O) $0

1926.416 E01

Other-than-serious 1 instance 1 exposed
Issued
Aug 3, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used:     a)  Fast Framing Inc. at 8581 East 21st Avenue, Denver, CO 80238:  On or before 7/30/11, the employer allowed employees to use a worn and frayed yellow electrical cord. The cord was used to power a Mag 77 Skilsaw, and a Rolair air compressor model 6820K170001, serial number 10010791.  Both tools were not double insulated.  The cord was plugged into a temporary panel with a ground fault circuit interrupter (GFCI).  Condition exposed employees to electrical shock hazards.    Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
Recent events (1)
  • — Z (O) $0

1926.502 B03

Other-than-serious 1 instance 3 exposed
Issued
Aug 3, 2011
Abate by
Aug 24, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(3):  Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:    a)  Fast Framing Inc. at 8581 East 21st Avenue, Denver, CO 80238:  On or before 7/30/11, the employer did not ensure that the guardrails around the stairway openings on both the main floor and the second floor were capable of withstanding a force of 200 pounds.  The horizontal guardrails consisted of construction grade 2 x 4's with posts that were 10.5 feet apart.  Conditions exposed employees to fall hazards of up to 20 feet to the basement.     Abatement note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").    Abatement note:  1926 Subpart M Appendix B provides that the posts shall be spaced not more than 8 feet apart.
Recent events (1)
  • — Z (O) $0

View Fast Framing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330967944.