Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: SPEEDWAY LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SPEEDWAY LLC in 4950 BURKHARDT AVE., DAYTON, OH 45431 (NAICS 447110). OSHA activity number 330927401.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Speedway LLC for free Get an email when a new federal OSHA severe-injury report for Speedway LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SPEEDWAY LLC
Site address
4950 BURKHARDT AVE.
City
DAYTON
State
OH
ZIP
45431
Mailing
4950 BURKHARDT AVE., DAYTON, OH 45431
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
447110
Employees
15
Ownership type
Private (A)

2 citations on file for this inspection.

1910.36 G02

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 28, 2011
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.36(g)(2):     Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.    The space immediately in front in front of the exit door for the back room was constricted down to 14 inches by stacked and stored items such as boxes and a mop bucket.
Recent events (2)
  • · I (S) $1606.5
  • · Z (S) $2295

1910.303 G01

Serious Gravity 1 1 exposed
Issued
Jul 28, 2011
Abate by
Jul 29, 2011
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:    It was not possible to walk within 28 inches of the two electric panels located in the back room due to tall stacking of storage materials directly in front of them.
Recent events (2)
  • · I (S) $1606.5
  • · Z (S) $2295

View Speedway LLC's full OSHA safety record →