ELK GROVE VILLAGE, IL ·
OSHA Inspection: ROLLEX CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROLLEX CORPORATION in 800 CHASE AVE, ELK GROVE VILLAGE, IL 60007 (NAICS 332322). OSHA activity number 330985417.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROLLEX CORPORATION
- Site address
- 800 CHASE AVE
- City
- ELK GROVE VILLAGE
- State
- IL
- ZIP
- 60007
- Mailing
- 800 CHASE AVE, ELK GROVE VILLAGE, IL 60007
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 92
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.178 L04 III
- Issued
- Oct 24, 2011
- Abate by
- Nov 15, 2011
- Penalty
- Initial $2,618 · Current $1,309 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years. a) Production- On or about 09/08/11, employees were required to operate forklifts without evaluation of operator performance every three years. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $1309
- · Z (S) $2618
1910.212 A01
- Issued
- Oct 24, 2011
- Penalty
- Initial $3,273 · Current $1,636 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) Production Area- On or about 09/08/11, the employer failed to maintain adequate barrier guards to prevent employees from getting hands/fingers caught in nip points created when aluminum sheets are being formed and cut on the PS-2 Soffit Starter Strip "Part S" and the F-4 8" Fascia SL-8 machines. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (S) $1636.25
- · Z (S) $3272.5
1910.212 A03 II
- Issued
- Oct 24, 2011
- Penalty
- Initial $3,273 · Current $1,636 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Production Area- On or about 09/08/11, the employer failed to provide guarding for the Niagara hydraulic press brake to prevent employees from having their fingers/hands in the point of operation during the operating cycles. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (S) $1636.25
- · Z (S) $3272.5
1910.305 G01 IV A
- Issued
- Oct 24, 2011
- Abate by
- Nov 15, 2011
- Penalty
- Initial $1,964 · Current $982 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure. a) Production Area- On or about 09/08/11, a 50 foot black extension cord energizing the #38 stamping press was used as a substitute for fixed wiring. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $981.5
- · Z (S) $1963.5
1910.22 A01
- Issued
- Oct 24, 2011
- Abate by
- Nov 15, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. Production Area- On or about 09/08/11, employees were exposed to tripping hazard from air hoses and electrical cords strewn over the shop floor in the press brake/stamping area. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.147 C06 II
- Issued
- Oct 24, 2011
- Abate by
- Nov 15, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed. The certification shall identify the machine or equipment on which the energy control procedure is being performed on, the date of inspection and the person performing the inspection. a) Production Area- On or about 09/08/11, the employer did not certify that periodic inspections were performed on employees authorized to lockout equipment. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Rollex Corporation
View Rollex Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330985417.