COLUMBUS, OH ·
OSHA Inspection: ARCHITECTURAL SYSTEMS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARCHITECTURAL SYSTEMS INC. in 4151 BRIDGEWAY AVE., COLUMBUS, OH 43213 (NAICS 238160). OSHA activity number 330986753.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCHITECTURAL SYSTEMS INC.
- Site address
- 4151 BRIDGEWAY AVE.
- City
- COLUMBUS
- State
- OH
- ZIP
- 43213
- Mailing
- 9042 HERITAGE DRIVE, PLAIN CITY, OH 43064
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 70
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1926.501 B10
- Issued
- Nov 25, 2011
- Abate by
- Nov 28, 2011
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section,each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall beprotected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrailsystem, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safetymonitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring systemalone [i.e. without the warning line system] is permitted. a. On the northside of the roof where employees were installing 24 guage screen wall panels, the employer did not install a fall protection system thereby exposing employees to a 50-60 foot fall hazard. b. On the southside of the roof, the employer failed to install a fall protection system thereby exposing employees to a 50 to 60 foot fall hazard.
Recent events (2)
- · I (S) $3430
- · Z (S) $4900
More inspections at Architectural Systems INC.
View Architectural Systems INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330986753.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.