Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: SOUTHERN FOODS GROUP, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTHERN FOODS GROUP, LLC in 5512 LEETSDALE DR., DENVER, CO 80246 (NAICS 112120). OSHA activity number 330987645.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southern Foods Group, LLC for free Get an email when a new federal OSHA severe-injury report for Southern Foods Group, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5512 LEETSDALE DR.
City
DENVER
State
CO
ZIP
80246
Mailing
5512 LEETSDALE DR., DENVER, CO 80246
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
112120
Employees
60
Ownership type
Private (A)

7 citations on file for this inspection.

1910.23 A02

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 9, 2012
Abate by
Mar 24, 2012
Penalty
Initial $2,168 · Current $1,300 Reduced
29 CFR 1910.23(a)(2): Every ladderway floor opening or platform shall be guarded by a standard railing with standardtoeboard on all exposed sides (except at entrance to opening), with the passage through the railing either provided with a swinging gate or so offsetthat a person cannot walk directly into the opening.    (a)	Southern Foods Group, LLC Dba Dillon Dairy at 5512 Leetsdale Dr., Denver, CO 80246: On and before 9/13/11, the employer did not ensure that standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level. This condition exposed employees to a fall hazard in the milk receiving area.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $1300
  • · Z (S) $2167.5

1910.23 C01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 9, 2012
Abate by
Mar 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standards railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)9i) through (v)), on all open sides except where there is entrance to a ramp, stairway, or fixed ladder:    (a) 	Southern Foods Group, LLC Dba Dillon Dairy at 5512 Leetsdale Dr., Denver, CO 80246: On and before 9/13/11, the employer did not ensure that open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)9i) through (v)), on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The platform in the milk cooler area was not guarded by standard railings or the equivalent. This condition exposed employees to a fall hazard.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 E

Serious Gravity 1 2 instances 3 exposed
Issued
Mar 9, 2012
Abate by
Mar 24, 2012
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.37(e): Employers must install and maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other emergencies:    (a)	Southern Foods Group, LLC Dba Dillon Dairy at 5512 Leetsdale Dr., Denver, CO 80246: On and before 9/13/11, the employer did not install and maintain an operable employee alarm system that has a distinctive signal or horn to warn employees of fire or other emergencies. This condition exposed employees to a fire or emergency hazard.    (b)	Southern Foods Group, LLC Dba Dillon Dairy at 5512 Leetsdale Dr., Denver, CO 80246: On and before 9/13/11, the employer did not install and maintain an operable ammonia alarm system that warns employees of an ammonia release. This condition exposed employees to inhalation hazards of ammonia.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.212 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Mar 9, 2012
Abate by
Mar 24, 2012
Penalty
Initial $3,400 · Current $2,040 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      (a)	Southern Foods Group, LLC Dba Dillon Dairy at 5512 Leetsdale Dr., Denver, CO 80246: On and before 9/13/11, the employer did not protect employees from hazards created by operating a portable hand grinder, with an unused portion of the grinder unguarded, the ingoing nip point of the plastic bottle conveyor and the unguarded belt on the ammonia system. This condition exposed employees to amputation and crush hazards.      1)	portable hand grinder  2)	plastic bottle conveyor   3) 	unguarded belt on ammonia system    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $2040
  • · Z (S) $3400

1910.243 C03

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 9, 2012
Abate by
Mar 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.243(c)(3): Vertical portable grinders. Safety guards used on machines known as right angle head or vertical portable grinders shall have a maximum exposure angle of 180 deg., and the guard shall be so located so as to be between the operator and the wheel during use. Adjustment of guard shall be such that pieces of an accidentally broken wheel will be deflected away from the operator.    (a)	Southern Foods Group, LLC Dba Dillon Dairy at 5512 Leetsdale Dr., Denver, CO 80246: On and before 9/13/11, the employer did not protect employees from hazards created by operating a portable hand grinder, with an unused portion of the grinder unguarded. This condition exposed employees to amputation hazards.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 G02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 9, 2012
Abate by
Mar 24, 2012
Penalty
Initial $2,168 · Current $1,300 Reduced
29 CFR 1910.303(g)(2)(i):  The employer did not ensure that live parts of electric equipment operating  at 50 volts or more were guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    (a)	Southern Foods Group, LLC Dba Dillon Dairy at 5512 Leetsdale Dr., Denver, CO 80246: On and before 9/13/11, the employer did not ensure that live parts of the electric pallet jack operating at 50 volts or more were guarded against accidental contact. The electrical pallet jack is located at a wet and damp area where the crate washing equipment is. This condition exposed employees to electrical hazards.     Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $1300
  • · Z (S) $2167.5

1910.146 C02

Other-than-serious 1 instance 3 exposed
Issued
Mar 9, 2012
Abate by
Mar 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:    (a)	Southern Foods Group, LLC Dba Dillon Dairy at 5512 Leetsdale Dr., Denver, CO 80246: On and before 9/13/11, the employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by permit spaces. The milk separator tank on site had been evaluated as permit required spaces. Employer did not identify these spaces by posting danger signs or by any other equally effective means. This condition exposed the employees to a confined space hazard.        Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Southern Foods Group, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330987645.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.