BUCYRUS, OH —
OSHA Inspection: COSAM CONTRACTING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COSAM CONTRACTING, INC. in 241 E. MANSFIELD, BUCYRUS, OH 44820 (NAICS 238160). OSHA activity number 330988809.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COSAM CONTRACTING, INC.
- Site address
- 241 E. MANSFIELD
- City
- BUCYRUS
- State
- OH
- ZIP
- 44820
- Mailing
- 6260 WAYNESBURG TIRO RD., TIRO, OH 44887
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Sep 26, 2011
- Abate by
- Oct 11, 2011
- Penalty
- Initial $9,240 · Current $4,620 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section,each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall beprotected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring systemalone [i.e. without the warning line system] is permitted. a) Cosam Contracting, Inc. worksite located at 241 E. Mansfield in Bucyrus, Ohio: On or about September 15, 2011, the employer did not assure employees were protected from falls while performing tasks associated with roofing. Employees performing roofing operations on a commercial roof were exposed to falls of approximately 19 feet and up to approximately 24 feet on the unprotected edges of the roof. Cosam Contracting, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(10), which was contained in OSHA inspection number 311611321, citation number 1, item number 1 and was affirmed as a final order on November 4, 2010, with respect to a workplace located at 238 N. Sandusky Ave., Bucyrus, Ohio. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (R) $4620
- — Z (R) $9240
1926.503 A01
- Issued
- Sep 26, 2011
- Abate by
- Oct 18, 2011
- Penalty
- Initial $9,240 · Current $0 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed inorder to minimize these hazards. a) Cosam Contracting, Inc. worksite located at 241 E. Mansfield in Bucyrus, Ohio: On or about September 15, 2011, the employer did not assure that employees were trained to recognize appropriate use of fall protection. A parapet wall was inadequate in providing fall protection, exposing employees performing roofing operations to fall hazards of approximately 19 feet and/or up to approximately 24 feet at the unprotected edges of the roof. Cosam Contracting, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.503(a)(1), which was contained in OSHA inspection number 311611321, citation number 1, item number 2 and was affirmed as a final order on November 4, 2009, with respect to a workplace located at 238 N. Sandusky Ave., Bucyrus, Ohio. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (O) $0
- — Z (R) $9240
More inspections at Cosam Contracting, INC.
View Cosam Contracting, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330988809.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.