OSHA Inspection: DCG ROOFING SOLUTIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DCG ROOFING SOLUTIONS, INC. in 420 W. DEMPSTER, MOUNT PROSPECT, IL 60056 (NAICS 238160). OSHA activity number 330989054.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DCG Roofing Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for DCG Roofing Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
420 W. DEMPSTER
City
MOUNT PROSPECT
State
IL
ZIP
60056
Mailing
1285 RAND ROAD, DES PLAINES, IL 60016
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

4 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 28, 2011
Abate by
Sep 29, 2011
Penalty
Initial $4,620 · Current $2,310 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:    a) Employees were exposed to the hazard of falling approximately 30 feet while working outside of warning lines without the use of a safety monitoring system or other fall protection.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2310
  • — Z (S) $4620

1926.502 F02 II

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Sep 28, 2011
Abate by
Sep 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface:    a) Warning lines located along the north edge of the roof deck were only 27 inches above the roof deck.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 28, 2011
Penalty
Initial $2,640 · Current $1,320 Reduced
29 CFR 1926.602(d) NOTE: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.178(l) of this Chapter.    29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a) The employer provided employees with a forklift truck without ensuring that the assigned operator was competent to operate the equipment safely, as demonstrated by the successful completion of forklift training and evaluation.    No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $1320
  • — Z (S) $2640

1926.501 B03

Repeat Gravity 10 6 instances 3 exposed
Issued
Sep 28, 2011
Abate by
Sep 29, 2011
Penalty
Initial $9,240 · Current $4,620 Reduced
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems:    a) Employees were exposed to the hazard of falling approximately 30 feet from the edge of the roof deck while signaling a crane during hoisting operations.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.      DCG Roofing Solutions, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(3) which was contained in OSHA inspection number 313934390, citation 1, item 2c, issued on June 8, 2010 and became final order on or about June 29, 2010.
Recent events (2)
  • — I (R) $4620
  • — Z (R) $9240

View DCG Roofing Solutions, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330989054.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.