WELLINGTON, OH —
OSHA Inspection: CHURCH ART GLASS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHURCH ART GLASS, INC. in 149 SOUTH MAIN STREET, WELLINGTON, OH 44090 (NAICS 238150). OSHA activity number 330989088.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHURCH ART GLASS, INC.
- Site address
- 149 SOUTH MAIN STREET
- City
- WELLINGTON
- State
- OH
- ZIP
- 44090
- Mailing
- 12 U S HIGHWAY 51 S P.O. BOX 177, CLINTON, KY 42031
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Oct 12, 2011
- Abate by
- Nov 2, 2011
- Penalty
- Initial $3,000 · Current $2,250 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(ii): The work platform was not planked or decked as much as possible and the remaining open space between the platform and the uprights shall not exceed 91/2 inches: AVD: The scaffold in use, from levels ranging from approximately eleven (11) feet above ground and higher were not planked all the way across as needed resulting in a fall hazard.
Recent events (2)
- — I (S) $2250
- — Z (S) $3000
1926.451 G01
- Issued
- Oct 12, 2011
- Abate by
- Nov 2, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Employees on a scaffold more than 10 feet above a lower level were not protected from falling to the lower level(s): AVD: The scaffold in use, from levels ranging from approximately eleven (11) feet above ground and higher were not protected from falling due to a lack of proper guardrails, i.e. midrails and toprails, both along the sides and ends of the platforms.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C
- Issued
- Oct 12, 2011
- Abate by
- Nov 2, 2011
- Penalty
- Initial $3,000 · Current $2,250 Reduced
General-duty citation text
29 CFR 1926.451(c): Supported scaffolds with a height to base width ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means: AVD: The scaffold in use was approximately 25 to 30 feet in height from ground level, above the 4:1 ratio of approximately 20 feet (5 foot wide base) and had no restraint (tie-offs) present.
Recent events (2)
- — I (S) $2250
- — Z (S) $3000
1926.451 E01
- Issued
- Oct 12, 2011
- Abate by
- Nov 2, 2011
- Penalty
- Initial $3,000 · Current $2,250 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, ramps, walkways, integral pre-fabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface were not in use: AVD: The workers did not have proper access to the scaffold as a step ladder was observed leaning on the cross bracing at the first level, and the sides and cross bracing of the scaffold were then used for access to the upper levels of the scaffold.
Recent events (2)
- — I (S) $2250
- — Z (S) $3000
1926.451 H02
- Issued
- Oct 12, 2011
- Abate by
- Nov 2, 2011
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(h)(1): In addition to wearing hard hats, each employee on a scaffold were not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, or screens: AVD: Worker(s) on the scaffold were not wearing hard hats and the scaffold had no kickplates (toeboards) in place on all work platforms at all levels.
Recent events (2)
- — I (O) $0
- — Z (S) $2400
1926.452 C02
- Issued
- Oct 12, 2011
- Abate by
- Nov 2, 2011
- Penalty
- Initial $3,000 · Current $2,250 Reduced
General-duty citation text
29 CFR 1926.452(c )(2): Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally: AVD: Cross bracing was missing on several levels of the scaffold including, but not limited to 4th, 5th and 6th levels south, 5th and 6th levels north.
Recent events (2)
- — I (S) $2250
- — Z (S) $3000
More inspections at Church ART Glass, INC.
View Church ART Glass, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238150)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330989088.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.