Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: STRANGERS HOME SERVICES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STRANGERS HOME SERVICES, INC. in 705 W. PRODUCER DRIVE, MERIDIAN, ID 83642 (NAICS 238140). OSHA activity number 331064782.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Strangers Home Services, INC. for free Get an email when a new federal OSHA severe-injury report for Strangers Home Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
705 W. PRODUCER DRIVE
City
MERIDIAN
State
ID
ZIP
83642
Mailing
3300 W. GRAND RAPIDS DRIVE, MERIDIAN, ID 83646
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.451 C02

Serious Gravity 1 2 instances 8 exposed
Issued
Oct 13, 2011
Penalty
Initial $1,300 · Current $750 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:      a) South side of structure, west of the rear entry; On or about 9/15/11 and at times prior thereto, a stand of tubular welded frame scaffold base plates were setting directly on the ground without mud sills having been installed prior to employees using the scaffold for installing stucco.    b) South side of structure, east of the rear entry; On or about 9/15/11 and at times prior thereto, a stand of tubular welded frame scaffold base plates were setting directly on the ground without mud sills having been installed prior to employees using the scaffold for installing stucco.    Note: Abatement certification is NOT required for this item.
Recent events (2)
  • · I (S) $750
  • · Z (S) $1300

1926.451 G01

Serious Gravity 1 2 instances 8 exposed
Issued
Oct 13, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    a) South side of structure, west of the rear entry; On or about 9/15/11 and at times prior thereto, a stand of tubular welded frame scaffold did not have guard rails installed across the ends of the second level prior to employees using the scaffold for installing stucco.    b) South side of structure, east of the rear entry; On or about 9/15/11 and at times prior thereto, a stand of tubular welded frame scaffold did not have guard rails installed across the ends of the second level prior to employees using the scaffold for installing stucco.    Note: Abatement certification is NOT required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B13

Serious Gravity 1 1 instance 8 exposed
Issued
Oct 13, 2011
Penalty
Initial $1,300 · Current $750 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.    a) South side of structure, roof area above rear entry; On or about 9/15/11 and at times prior thereto, two employees were installing stucco on the gable while standing on a sloped roof without a means of fall protection.     Note: Abatement certification is NOT required for this item.
Recent events (2)
  • · I (S) $750
  • · Z (S) $1300

View Strangers Home Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331064782.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.