Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED STATES BORDER PATROL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNITED STATES BORDER PATROL in 2411 BOSWELL ROAD, CHULA VISTA, CA 91914 (NAICS 921130). OSHA activity number 331070169.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United States Border Patrol — free Get an email when a new federal OSHA severe-injury report for United States Border Patrol is published. One employer, no account, unsubscribe in one click.
Site address
2411 BOSWELL ROAD
City
CHULA VISTA
State
CA
ZIP
91914
Mailing
2411 BOSWELL ROAD, CHULA VISTA, CA 91914
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
921130
Employees
165
Ownership type
D

10 citations on file for this inspection.

1910.132 D01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 4, 2011
Abate by
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1)(i):     The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:    a) At the Maintenance Unit, Carpentry Shop - On or about 8/15/11, an employee used safety glasses without side shields while operating a Rockwell Unisaw. Use of safety glasses without shields was not consistent with the employer's job hazard assessment.
Recent events (1)
  • — Z (S) $0

1910.178 L04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 4, 2011
Abate by
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii):     An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years:    a) At the Maintenance Unit, Carpentry Shop - On or about 8/15/11, the employer allowed employees to operate a forklift without having been evaluated as required by the standard.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 4, 2011
Abate by
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) At the Maintenance Unit, Welding Shop - On or about 8/15/11 and at times prior thereto, a drill press was being operated without a chip guard.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 4, 2011
Abate by
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4):     Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    a) At the Maintenance Unit, Welding Shop - On or about 8/15/11, the right and left grinding wheels on a pedestal grinder were more than one eighth of an inch from the work rests.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 4, 2011
Abate by
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):     The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    a) At the Maintenance Unit, Welding Shop - On or about 8/15/11, the distance between the tongue guards and the right and left grinding wheels were greater that one fourth inch.
Recent events (1)
  • — Z (S) $0

1910.253 B04 I

Serious Gravity 5 1 instance 30 exposed
Issued
Nov 4, 2011
Abate by
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i):     Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:    a) At the Maintenance Unit, Welding cylinder storage cage - On or about 8/15/11, cylinders of oxygen were stored next to cylinders of acetylene.
Recent events (1)
  • — Z (S) $0

1910.303 B01 II

Serious Gravity 5 4 instances 165 exposed
Issued
Nov 4, 2011
Abate by
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1)(ii):     Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    a) At Ms. Abad's office, underneath desk - On or about 8/10/11, a cutout in the wall underneath a 120 VAC outlet exposed employees to inadvertent contact with live electrical parts.    b) At Classroom 189, right of door -  On or about 8/10/11, an electrical outlet had a broken portion so that the cover did not adequately protect against inadvertent contact with live parts.    c) At Classroom 189, back  wall of room - On or about 8/10/11, an electrical outlet had a broken portion so that the cover did not adequately protect against inadvertent contact with live parts.    d) At the Conference Room, left of sink behind microwave - On or about 8/10/11, an electrical outlet cover was not securely fastened and flush so that the cover did not adequately protect against inadvertent contact with live parts.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 165 exposed
Issued
Nov 4, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) At Mr. Alonzo's cubicle, underneath desk - On or about 8/10/11, two surge protectors were daisy chained together to power computer equipment.    b) In the Media office, underneath Mr. Ramos' desk - On or about 8/10/11, two surge protectors were daisy chained together to power computer equipment.    c) In the Finance office, underneath desks - On or about 8/10/11, two sets of surge protectors were daisy chained together to power computer equipment.
Recent events (1)
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 1 3 instances 4 exposed
Issued
Nov 4, 2011
Abate by
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii):     Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded.    a) At the Warehouse - On or about 8/10/11, the area in front of an electrical switch box was used to store computer equipment.    b)At the Break room ,adjacent to door - On or about 8/10/11, the area in front of an electrical panel was used to store a trash can.    c) At the Maintenance Unit, Carpentry shop - On or bout 8/15/11, the area in front of two electrical switch boxes was used to store wood scraps.
Recent events (1)
  • — Z (S) $0

1960.66 D

Other-than-serious 4 instances 237 exposed
Issued
Nov 4, 2011
Abate by
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1960.66(d):     The federal agency employer did not maintain 29 CFR 1904.29(a) records as required by CFR 1960.66(d).  A Log of all Work-Related Injuries and Illnesses (OSHA Form 300), and/or the Summary of Work-Related Injuries and Illnesses, (OSHA Form 300-A), and/or the Injury and Illness Incident Report (OSHA Form 301) or equivalent forms were not kept by the establishment:    a) At the establishment - On or about 8/10/11, the OSHA 300 annual summary for 2006 was not kept by the establishment.    b) At the establishment - On or about 8/10/11, the OSHA 300 annual summary for 2007 was not kept by the establishment.    c) At the establishment - On or about 8/10/11, the OSHA 300 annual summary for 2008 was not kept by the establishment.    d) At the establishment - On or about 8/10/11, the OSHA 300 annual summary for 2009 was not kept by the establishment.
Recent events (1)
  • — Z (O) $0

View United States Border Patrol's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331070169.