Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UTILICON CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UTILICON CORPORATION in 1516 WEST MOUND STREET, COLUMBUS, OH 43223 (NAICS 237110). OSHA activity number 331081604.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Utilicon Corporation — free Get an email when a new federal OSHA severe-injury report for Utilicon Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1516 WEST MOUND STREET
City
COLUMBUS
State
OH
ZIP
43223
Mailing
888 E. 70TH ST., CLEVELAND, OH 44103
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.651 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 5, 2012
Abate by
Feb 4, 2012
Penalty
Initial $10,780 · Current $7,000 Reduced
29 CFR 1926.651(k)(1):     Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.    a) At the site located along West Mound Street in Columbus, Ohio, the person that identified himself as the competent person on-site demonstrated inadequate skills necessary to recognize hazards associated with timber shoring, such as, but not limited to, missing cross-braces,  damaged lumber, and inadequate sized lumber for the whalers and cross-braces.     The Utilicon Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent (1926.651(k)(1)), which was contained in OSHA inspection number 311605968, citation number 1, item number 3a, and was affirmed as a final order on November 14, 2008 with respect to a workplace located at U.S. 6 & Vineyard Rd., Avon Lake, Ohio 44012.
Recent events (3)
  • — F (S) $7000
  • — C (R) $10780
  • — Z (R) $10780

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 5, 2012
Abate by
Feb 4, 2012
Penalty
Initial $26,950 · Current $7,000 Reduced
29 CFR 1926.652(a)(1):     Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).     a)  On or about October 26, 2011 at the site located along West Mound Street in Columbus, Ohio, contractors were conducting construction work on a 20 inch water main in an open excavation, approximately 77 inches deep with an inadequate cave-in protection system.  The employer was using timber shoring at the site that did not meet the minimum specifications as outlined in 29 CFR 1926, Subpart P, Appendix C.    The Utilicon Corporation was previously cited for a violation of this occupational safety and helath standard or its equivalent (1926.652(a)(1)), which was contained in OSHA inspection number 311605968, citation number 1, item number 3b, and was affirmed as a final order on November 14, 2008 with respect to a workplace located at U.S. 6 & Vineyard Rd., Avon Lake, Ohio 44012.    The Utilicon Corporation was previously cited for a violation of this occupational safety and helath standard or its equivalent (1926.652(a)(1)), which was contained in OSHA inspection number 314108093, citation number 2, item number 1, and was affirmed as a final order on May 19, 2010 with respect to a workplace located at Old Freeport Road, Pittsburgh, PA.
Recent events (3)
  • — F (S) $7000
  • — C (R) $26950
  • — Z (R) $26950

1926.652 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 5, 2012
Abate by
Jan 10, 2012
Penalty
Initial $1,000 · Current $1,000
29 CFR 1926.652(c)(1):   Option (1) - Designs using appendices A, C and D. Designs for timber shoring in trenches shall be determined in accordance with the conditions and requirements set forth in appendices A and C to this subpart. Designs for aluminum hydraulic shoring shall be in accordance with paragraph (c)(2) of this section, but if manufacturer's tabulated data cannot be utilized, designs shall be in accordance with appendix D:    a.  at the site located along West mound Street in Columbus, Ohio, timber shoring did not meet requirements set forth in appendices A and C to Subpart B - excavations.
Recent events (3)
  • — C (S) $1000
  • — F (S) $1000
  • — Z (S) $1000

View Utilicon Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331081604.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.