CINCINNATI, OH ·
OSHA Inspection: H NAGEL & SON, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of H NAGEL & SON, INC. in 2641 SPRING GROVE AVE., CINCINNATI, OH 45214 (NAICS 311211). OSHA activity number 331081901.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H NAGEL & SON, INC.
- Site address
- 2641 SPRING GROVE AVE.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45214
- Mailing
- 2428 CENTRAL PARKWAY, CINCINNATI, OH 45214
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311211
- Employees
- 14
- Ownership type
- Private (A)
Citations
15 citations on file for this inspection.
1910.23 A08
- Issued
- Dec 2, 2011
- Penalty
- Initial $2,100 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk shall be guarded: guarding or covering. a) In the employees' changing room, employees were exposed to floor holes from where material chutes and piping had been removed.
Recent events (2)
- · I (S) $1680
- · Z (S) $2100
1910.23 C01
- Issued
- Dec 2, 2011
- Abate by
- Jan 31, 2012
- Penalty
- Initial $2,800 · Current $2,240 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall beguarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides, a) In the MIDDS outside truck filling area the valve platfrom was not equipped with a guard railing system. b) Employees were required to work from top of bulk grain and flour trucks to check product levels in the truck exposing them to falls in excess of eight(8) feet.
Recent events (2)
- · I (S) $2240
- · Z (S) $2800
1910.178 L04 III
- Issued
- Dec 2, 2011
- Abate by
- Jan 18, 2012
- Penalty
- Initial $2,100 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. a) Forklift operaotrs were not evaluated every three years to ensure the effectiveness of the training.
Recent events (2)
- · I (S) $1680
- · Z (S) $2100
1910.147 C01
- Issued
- Dec 2, 2011
- Abate by
- Feb 29, 2012
- Penalty
- Initial $2,800 · Current $2,240 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy controlprocedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine orequipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall beisolated from the energy source and rendered inoperative. a) The company did not develop and implement a program to establish energy control procedures, training and periodic reviews to address control of hazardous energy when performing servicing and maintenance of equipment such as but not limited to changing of mixers.
Recent events (2)
- · I (S) $2240
- · Z (S) $2800
1910.147 D04 I
- Issued
- Dec 2, 2011
- Abate by
- Feb 29, 2012
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. a) On or about October 25, 2011 a lockout device was attached by only one employee when two employees were involved in maintenance on the Mixer.
Recent events (2)
- · I (S) $0
- · Z (S) $4200
1910.219 C02 I
- Issued
- Dec 2, 2011
- Abate by
- Jan 31, 2012
- Penalty
- Initial $3,500 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform,excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by atrough enclosing sides and top or sides and bottom of shafting as location requires. a) Bran mill drive shaft was not guarded to prevent employee exposure to rotating parts. b) MIDDS line drive shaft was not guarded to prevent employee exposure to rotating parts. c) The entire line shaft incluging belts, pulley, chain and sprocket drives were not guarded to prevent employee exposure to rotating parts. d) Drive shaft on #2 tank was not guarded to prevent employee exposure to rotating parts. e) Drive shaft on the Incline auger was not guarded to prevent employee exposure to rotating parts.
Recent events (2)
- · I (S) $2800
- · Z (S) $3500
1910.219 E03 I
- Issued
- Dec 2, 2011
- Abate by
- Jan 31, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs(m) and (o) of this section. a) Guarding was not provided on the motor drive belt on the roof to the auger exposing employees to pinch points. b) Guarding was not provided on the motor drive belt for the auger attached to Bin #2. c) Guarding was not provided on the motor drive belt for the auger attached to Bin #4. d) Guarding was not provided on the motor drive belt on Bran mill. e) Guarding was not provided on the motor drive belt on the shaker. f) Guarding was not provided on the motor drive belt on the vacuum line. g) Guarding was not provided on the motor drive belt on the drive line.
Recent events (2)
- · I (S) $0
- · Z (S) $3500
1910.219 F03
- Issued
- Dec 2, 2011
- Abate by
- Mar 16, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided.This subparagraph does not apply to manually operated sprockets. a) Chains and sprockets were not guarded on the MIDDS line.
Recent events (2)
- · I (S) $0
- · Z (S) $2800
1910.272 E01
- Issued
- Dec 2, 2011
- Abate by
- Jan 18, 2012
- Penalty
- Initial $2,100 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.272(e)(1): The employer shall provide training to employees at least annually and when changes in job assignment will expose them to new hazards in the grain/flour handling facilities. Current employees, and new employees prior to starting work, shall be trained in accordance with paragraph (i) and (ii): a) Employees had not received training at least annually on dust accumulation, ignition sources and specific clearing procedures for chocked legs, or ignition hazards when working at the grain handling facility.
Recent events (2)
- · I (S) $1680
- · Z (S) $2100
1910.272 F02
- Issued
- Dec 2, 2011
- Abate by
- Dec 23, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.272(f)(2): The permit shall certify that the requirements contained in 1910.252(a) have been implemented prior to beginning the hot work operations. The permit shall be kept on file until completion of the hot work operations. a) Hot work permit was not issed prior to allowing welders to begin welding operation.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.272 E02
- Issued
- Dec 2, 2011
- Abate by
- Jan 18, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.272(e)(2): Employees assigned special tasks, such as bin entry and handling of flammable or toxic substances, shall be provided training to perform these tasks safely. a) Employees had not been trained on specfic procedures such as but not limited to engulfment and mechanical hazards and how to avoid them, testing of the space(s) to determine if any flammable/combustable materials (flour and dust)were present and for oxygen levels, recognition and preventive measures for the hazards related to dust/flour accumulation and ignition sources.
Recent events (2)
- · I (S) $0
- · Z (S) $2800
1910.303 G02 I
- Issued
- Dec 2, 2011
- Abate by
- Feb 29, 2012
- Penalty
- Initial $2,800 · Current $2,240 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a) Employees were expopsed to shock, or electrocution hazard(s) in that they were resetting tripped breakers for the Hammer Mill and Break rolls #1 and #2 and the covers had been removed from the boxes, exposing live parts.
Recent events (2)
- · I (S) $2240
- · Z (S) $2800
1910.305 B01 II
- Issued
- Dec 2, 2011
- Abate by
- Feb 29, 2012
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a) The knockout on the electrical disconnect box for the wheat clean area was not closed.
Recent events (2)
- · I (S) $0
- · Z (S) $2100
1910.307 C
- Issued
- Dec 2, 2011
- Abate by
- Jan 18, 2012
- Penalty
- Initial $2,800 · Current $2,240 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations shall be intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location.: a) The lighting in the MIDDS filling station was not approved for a Class II location. b) The battery chargers in the lift truck and pallet jacks charging areas were not intrinsically safe and therefor not approved for a Class II location..
Recent events (2)
- · I (S) $2240
- · Z (S) $2800
1910.146 C01
- Issued
- Dec 2, 2011
- Abate by
- Jan 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(1): The employer shall evaluate the workplace to determine if any spaces are permit-required confined spaces. a) The company had not conducted an evalution to determine whether spaces such as the dump pits and bins/silos were permit required confined spaces.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at H Nagel & SON, INC.
View H Nagel & SON, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311211)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331081901.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.