AKRON, OH ·
OSHA Inspection: H.M. MILLER CONSTRUCTION CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of H.M. MILLER CONSTRUCTION CO. in COPLEY RD. & PEERLESS AVE., AKRON, OH 44320 (NAICS 238910). OSHA activity number 331082008.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H.M. MILLER CONSTRUCTION CO.
- Site address
- COPLEY RD. & PEERLESS AVE.
- City
- AKRON
- State
- OH
- ZIP
- 44320
- Mailing
- P.O. BOX 131, MOGADORE, OH 44260
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 87
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.404 B01 I
- Issued
- Nov 10, 2011
- Abate by
- Nov 12, 2011
- Penalty
- Initial $3,850 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: On or about 10/28/11 during the installation of a branch saddle for a gas main, the employer did not ensure that a gas powered generator that was being used to power a water pump had ground fault circuit interruption.
Recent events (3)
- · F (S) $3000
- · C (S) $3850
- · Z (S) $3850
1926.404 F07 IV
- Issued
- Nov 10, 2011
- Abate by
- Nov 12, 2011
- Penalty
- Initial $3,850 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.404(f)(7)(iv): Equipment connected by cord and plug was not grounded: On or about 10/28/11 during the installation of a branch saddle for a gas main, the employer did not ensure that an electrical cord that was powering a water pump had a ground plug.
Recent events (3)
- · F (S) $3000
- · C (S) $3850
- · Z (S) $3850
1926.651 C02
- Issued
- Nov 10, 2011
- Penalty
- Initial $15,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: On or about 9/25/11 during excavation activities, the employer did not ensure a safe means of egress was used when exiting a trench that measured 25 feet in length, 2 feet in width at the bottom of the trench, and ranged between 4 and 5.5 feet in depth. The unprotected trench did not exceed 4.7 feet but the depth including concrete that was on top of the soil measured 5.5 feet in depth. H.M. MILLER CONSTRUCTION CO. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD CFR 1926.651(C) (2), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 312545049, CITATION NUMBER 01, ITEM NUMBER 01 AND WAS AFFIRMED AS A FINAL ORDER ON 11/06/08, WITH RESPECT TO A WORKPLACE LOCATED AT 4182 STATE RT. 43 KENT, OHIO 44240. H.M. MILLER CONSTRUCTION CO. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD CFR 1926.651(C) (2), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315110940, CITATION NUMBER 01, ITEM NUMBER 01 AND WAS AFFIRMED AS A FINAL ORDER ON 12/29/10, WITH RESPECT TO A WORKPLACE LOCATED AT 1751 BRITTAN RD. AKRON, OHIO 44260.
Recent events (3)
- · F (R) $0
- · C (R) $15400
- · Z (R) $15400
1926.1053 B09
- Issued
- Nov 10, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear: On or about 10/28/11 during the installation of a branch saddle for a gas main, the employer did not ensure that the area around the base of a portable ladder was clear for safe egress.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
More inspections at H.M. Miller Construction CO.
View H.M. Miller Construction CO.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331082008.