KODIAK, AK —
OSHA Inspection: MKB CONSTRUCTORS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MKB CONSTRUCTORS in USCG STATION KODIAK WHARF UPGRADE PROJECT, KODIAK, AK 99615 (NAICS 237990). OSHA activity number 331087452.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MKB CONSTRUCTORS
- Site address
- USCG STATION KODIAK WHARF UPGRADE PROJECT
- City
- KODIAK
- State
- AK
- ZIP
- 99615
- Mailing
- 4753 WEST 80TH, ANCHORAGE, AK 99502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237990
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.152 E04
- Issued
- Dec 8, 2011
- Abate by
- Dec 22, 2011
- Penalty
- Initial $2,520 · Current $2,520
General-duty citation text
29 CFR 1926.152(e)(4): The dispensing units shall be protected against collision damage. Outdoor fuel dispensing tank: On or about 3 November 2011, and times prior thereto, the fuel tank in the yard area was not protected against vehicular collision damage; exposing employees to fire and chemical hazards.
Recent events (2)
- — I (O) $2520
- — Z (S) $2520
1926.451 E01
- Issued
- Dec 8, 2011
- Abate by
- Dec 15, 2011
- Penalty
- Initial $3,780 · Current $2,268 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portableladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps,walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall beused. Crossbraces shall not be used as a means of access. Wharf Project: On or about 11/3/2011, and times prior thereto, employees were accessing supported scaffolds from floats without ladders or other means to facilitate safe passage; exposing employees of fall hazards onto steel support beams of the wharf or into the water.
Recent events (2)
- — I (S) $2268
- — Z (S) $3780
1926.451 G01 VII
- Issued
- Dec 8, 2011
- Abate by
- Dec 15, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4)of this section. Wharf Project: On or about 11/3/2011, and times prior thereto, employees were working on supported scaffolds to perform piping installation and insulation operations; exposing employees of fall hazards of over 10 feet onto steel support beams of the wharf or into the water.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- Dec 8, 2011
- Abate by
- Jan 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. Cargo Wharf Area: On or about 3 November 2011, and times prior thereto, the forklift operator operating the Caterpillar all-terrain forklift for the site had not been evaluated on his performance since training conducted in April 1999.
Recent events (1)
- — Z (O) $0
1926.351 B04
- Issued
- Dec 8, 2011
- Abate by
- Jan 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.351(b)(4): Cables in need of repair shall not be used. When a cable, other than the cable lead referred to inparagraph (b)(2) of this section, becomes worn to the extent of exposing bare conductors, the portion thus exposed shall be protected by means ofrubber and friction tape or other equivalent insulation. MKB work site: On or about November 3, 2011 and times prior thereto, arc welding cable was used that had exposed conductors. This exposed employees to possible shock hazards if they were to come in contact with the conductor.
Recent events (1)
- — Z (O) $0
More inspections at MKB Constructors
View MKB Constructors's full OSHA safety record →
More inspections in this industry (NAICS 237990)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331087452.