MERIDIAN, ID —
OSHA Inspection: ADA-CAN CONSTRUCTION, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ADA-CAN CONSTRUCTION, INC in LOT 11 BLK 10, MERIDIAN, ID 83680 (NAICS 238130). OSHA activity number 331089706.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADA-CAN CONSTRUCTION, INC
- Site address
- LOT 11 BLK 10
- City
- MERIDIAN
- State
- ID
- ZIP
- 83680
- Mailing
- 1550 ARTESIAN ROAD, EAGLE, ID 83616
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 2, 2011
- Abate by
- Dec 5, 2011
- Penalty
- Initial $2,400 · Current $900 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Jobsite: On November 10, 2011 and times prior thereto employees performed sheathing activities on a six in twelve and seven in twelve pitched roof without a fall protection system in place. b) Jobsite: On November 10, 2011 and times prior thereto employees performing framing activities were exposed to a fall hazard from the second floor level where a guardrail system was not in place along an open sided floor. Note) Abatement certification IS required for this item.
Recent events (2)
- — I (S) $900
- — Z (S) $2400
1926.503 A02 II
- Issued
- Dec 2, 2011
- Abate by
- Feb 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(2)(ii): The employer did not assure that each employee had been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Jobsite: On November 10, 2011 and times prior thereto the responsible person on site and employees performing framing activities were not familiar with fall protection systems required for residential construction. b) Jobsite: On November 10, 2011 and times prior thereto the responsible person and employees performing framing activities did not recognize the hazard of an open sided floor, and take action to minimize or eliminate this hazard. Note) Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1052 C01 II
- Issued
- Dec 2, 2011
- Abate by
- Dec 5, 2011
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having more than four risers or rising more than 30 inches was not equipped with one stairrail system along each unprotected side or edge: a) Jobsite: On November 10, 2011 and times prior thereto the interior stairway used for access to and from the second floor level did not have a stairrail system in place. Stairway had approximately 11 risers. Note) Abatement certification IS required for this item.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1926.1052 C12
- Issued
- Dec 2, 2011
- Abate by
- Dec 5, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems: a) Jobsite: On November 10, 2011 and times prior thereto employees performing framing activities were exposed to a fall hazard at the stairway landing where a guardrail system was not in place. Note) Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 B02
- Issued
- Dec 2, 2011
- Abate by
- Dec 5, 2011
- Penalty
- Initial $120 · Current $100 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Jobsite: On November 10, 2011 and times prior thereto, two seperate metal, four-way electrical junction boxes were used with flexible cords as part of the temporary power system for tools and equipment. Note 1) Ada-Can Construction, Inc ., was previously cited for a violation of this Occupational Safety and Health standard which was contained in OSHA inspection number 313352601, citation 2, item 2, and was affirmed as a final order on August 18, 2010, with respect to a workplace located at 2542 Vizcaya, Eagle, ID. Note 2) Abatement certification and documention ARE required for this item.
Recent events (2)
- — I (R) $100
- — Z (R) $120
More inspections at Ada-Can Construction, INC
View Ada-Can Construction, INC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331089706.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.