OSHA Inspection: AMERICAN INSULATING WINDOW COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMERICAN INSULATING WINDOW COMPANY, INC. in 358 S NAVAJO ST, DENVER, CO 80223 (NAICS 332321). OSHA activity number 331090589.

Watch American Insulating Window Company, INC. — free Get an email when a new federal OSHA severe-injury report for American Insulating Window Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
358 S NAVAJO ST
City
DENVER
State
CO
ZIP
80223
Mailing
358 S. NAVAJO STREET, DENVER, CO 80223
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
24
Ownership type
A

6 citations on file for this inspection.

1910.157 C01

Serious Gravity 1 3 instances 6 exposed
Issued
Jan 6, 2012
Abate by
Jan 30, 2012
Penalty
Initial $1,530 · Current $918 Reduced
CFR 1910.157(c)(1):  The employer failed to provide portable fire extinguishers and mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury    	(a)	American Window Insulating Company, Inc. 358 S. Navajo Street, Denver, CO 80223:  On and before November 16, 2011, the controlling and exposing employer failed to position portable fire extinguishers so that they were readily accessible to employees.  Specifically, three portable CO2 extinguishers were mounted on walls in the main welding area in locations where employees could not access them safely due to material being stored in front of them.  Condition exposed employees to fire hazards and lack of adequate fire fighting equipment.
Recent events (2)
  • — I (S) $918
  • — Z (S) $1530

1910.157 C04

Serious Gravity 1 1 instance 8 exposed
Issued
Jan 6, 2012
Abate by
Jan 30, 2012
Penalty
Initial $0 · Current $0
CFR 1910.157(c)(4):  The employer failed to assure that portable fire extinguishers were maintained in a fully charged and operable condition and kept in their designated places at all times except during use.    	(a)	American Window Insulating Company, Inc. 358 S. Navajo Street, Denver, CO 80223:  On and before November 16, 2011, the controlling and exposing employer failed to assure that portable fire extinguishers were maintained in a fully charged condition.  Specifically, a portable fire extinguisher located in the canvas cutting area was observed to have been discharged and was still mounted on the wall. Condition exposed employees to fire hazards and lack of adequate fire fighting equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 D02

Serious Gravity 1 1 instance 8 exposed
Issued
Jan 6, 2012
Abate by
Jan 30, 2012
Penalty
Initial $0 · Current $0
CFR 1910.157(d)(2):  The employer failed to distribute portable fire extinguishers for use by employees on Class A fires so that the travel distance for employees to any extinguisher was 75 feet (22.9 m) or less.     	(a)	American Window Insulating Company, Inc. 358 S. Navajo Street, Denver, CO 80223:  On and before November 16, 2011, the controlling and exposing employer failed to distribute portable fire extinguishers for use on class A fires so that the travel distance for employees to any extinguisher was 75 feet or less.  Specifically, only one portable CO2 extinguisher was mounted on the wall in the paint and powder coating area, and it was blocked and located near the entrance at a distance of well over 75 feet from two employee work stations at the far end of the paint and assembly area.  Condition exposed employees to fire hazards and lack of adequate fire fighting equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 B03 I

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 6, 2012
Abate by
Jan 30, 2012
Penalty
Initial $1,800 · Current $1,080 Reduced
CFR 1910.304(b)(3)(i): The employer failed to ensure that all 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops had ground-fault circuit-interrupters protection of personnel.    	(a)	American Insulating Window Company, Inc. 358 S. Navajo Street, Denver, CO 80223:  On and before November 16, 2011, the employer did not ensure that an electrical receptacle/outlet installed in the main production areas bathroom on a water wall was of the ground fault circuit interrupter type. Condition exposed employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $1080
  • — Z (S) $1800

1910.303 F02

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 6, 2012
Abate by
Jan 30, 2012
Penalty
Initial $0 · Current $0
CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.    	(a)	American Insulating Company, 358 S. Navajo Street, Denver, CO 80223:  On and before November 16, 2011, the main service panel in the main production area located near the main bay doors was not clearly marked so that every over currents device purpose was clearly indicated. This condition exposed employees to the hazard of unexpected energization of a machine which they thought they had electrically isolated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II B

Other-than-serious 1 instance 6 exposed
Issued
Jan 6, 2012
Abate by
Feb 17, 2012
Penalty
Initial $0 · Current $0
CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy were not developed for all of the machinery on site;    	(a)	American Insulating Window Company, 358 S. Navajo Street, Denver, CO 80223:  On and before November 16, 2011, the controlling employer did not ensure that specific procedures for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy were developed for all of the machinery which required it on site, such as the main cutting saw and powder coating oven. This condition exposed employees to amputation and point of operation hazards while servicing machinery.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0