BEDFORD, OH ·
OSHA Inspection: TENDON MANUFACTURING INCORPORATED
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TENDON MANUFACTURING INCORPORATED in 20805 AURORA ROAD, BEDFORD, OH 44146 (NAICS 332710). OSHA activity number 331092833.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TENDON MANUFACTURING INCORPORATED
- Site address
- 20805 AURORA ROAD
- City
- BEDFORD
- State
- OH
- ZIP
- 44146
- Mailing
- 20805 AURORA ROAD, BEDFORD, OH 44146
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 48
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.107 I08
- Issued
- Mar 13, 2012
- Abate by
- Apr 12, 2012
- Penalty
- Initial $3,500 · Current $1,600 Reduced
General-duty citation text
29 CFR 1910.107(i)(8): The electrical equipment was not interlocked with the ventilation of the spraying area such that the equipment cannot be operated unless the ventilation fans are in operation: On or about November 21, 2011, the hand spraying equipment was not interlocked with the ventilation in the powder coat booth to prevent operation of the equipment without the ventilation fans.
Recent events (2)
- · I (S) $1600
- · Z (S) $3500
1910.157 G02
- Issued
- Mar 13, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: On or about November 21, 2011, although portable fire extinguishers were available for use, employees were not trained initially or annually thereafter. Note: Applies where all employees are expected to fight fires.
Recent events (2)
- · I (O) $0
- · Z (S) $2800
1910.178 L01 I
- Issued
- Mar 13, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about November 21, 2011, employees operating powered industrial trucks were not provided with operator training.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.212 A05
- Issued
- Mar 13, 2012
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: On or about November 21, 2011, the blades of the pedestal fan outside of the powder coat booth were unguarded.
Recent events (2)
- · I (O) $0
- · Z (S) $2100
1910.303 B02
- Issued
- Mar 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about November 21, 2011, the pedestal fan was not intended for industrial use.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Mar 13, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about November, 21, 2011, the employer did not provide hazard communication training to employees exposed to chemicals such as, but not limited to liquefied petroleum gas, compressed gases (i.e. oxygen), liquid nitrogen, combustible powder coat, and general lubricants.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.134 K06
- Issued
- Mar 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: On or about November 21, 2011, the employer did not provide the basic advisory information in Appendix D of the Respiratory Protection standard to employees voluntarily wearing dust masks when powder coating.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Tendon Manufacturing Incorporated
View Tendon Manufacturing Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331092833.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.