Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: TENDON MANUFACTURING INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TENDON MANUFACTURING INCORPORATED in 20805 AURORA ROAD, BEDFORD, OH 44146 (NAICS 332710). OSHA activity number 331903849.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tendon Manufacturing Incorporated for free Get an email when a new federal OSHA severe-injury report for Tendon Manufacturing Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
20805 AURORA ROAD
City
BEDFORD
State
OH
ZIP
44146
Mailing
20805 AURORA ROAD, BEDFORD, OH 44146
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
48
Ownership type
Private (A)

4 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 2 instances 1 exposed
Issued
Mar 14, 2012
Abate by
Oct 31, 2012
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    The following press brakes, operated by foot pedal, did not have any point of operation guarding:    (a)  Accur Press Press Brake;    (b)  Wyson Press brake
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.303 G01

Other-than-serious 1 instance 1 exposed
Issued
Mar 14, 2012
Abate by
Apr 13, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment    The 240V disconnect was blocked by a table.  The disconnects powered the turret presses.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2100

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Apr 13, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    The company did not establish and utilize a program to protect employees involed with servicing and maintenance of machines and equipment from the unexpected energizing, start up or release of stored energy.  Energy sources included, but are not limited to, electrical, pneumatic, hydraulic, etc.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3500

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Apr 13, 2012
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A):     Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    On or before 1/31/12, all authorized employees did not receive training in the recognition of hazardous energy sources, the type and magnitude of the energy available to the workplace, and the methods and means necessary for energy isolation and control.  Equipment includes, but is not limited to, presses, press brakes, etc.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3500

View Tendon Manufacturing Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331903849.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.