Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CATTY CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CATTY CORPORATION in 6111 WHITE OAKS DR., HARVARD, IL 60033 (NAICS 322221). OSHA activity number 331096727.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Catty Corporation for free Get an email when a new federal OSHA severe-injury report for Catty Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
CATTY CORPORATION
Site address
6111 WHITE OAKS DR.
City
HARVARD
State
IL
ZIP
60033
Mailing
6111 WHITE OAKS DR., HARVARD, IL 60033
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322221
Employees
56
Ownership type
Private (A)

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 3 exposed
Issued
Apr 9, 2012
Abate by
May 9, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    In the Slitting Department, the ingoing nip points of the rewind rollers, on the following machines,  were not guarded:       a. Slitter 631     b. Slitter 632     c. Slitter 651     d. Slitter 652    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $1960
  • · Z (S) $2800

1910.147 C06 II

Other-than-serious 1 instance 3 exposed
Issued
Apr 9, 2012
Abate by
May 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):     The employer did not certify that periodic inspections of the energy control procedures had been performed:    Catty Corporation did not certify their periodic/annual inspection of their lockout program.    Abatement certification is required for this item in accordance with 29 CFR 1903.19(c)
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Catty Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331096727.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.