YIGO, GU —
OSHA Inspection: UNITED MECHANICAL
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of UNITED MECHANICAL in HOUSING BUILDING 25003, ANDERSEN AFB, YIGO, GU 96929 (NAICS 238220). OSHA activity number 331099812.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED MECHANICAL
- Site address
- HOUSING BUILDING 25003, ANDERSEN AFB
- City
- YIGO
- State
- GU
- ZIP
- 96929
- Mailing
- P.O. BOX 25385 GMF, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.150 C01 VIII
- Issued
- Feb 15, 2012
- Abate by
- Feb 23, 2012
- Penalty
- Initial $1,620 · Current $1,620
General-duty citation text
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers shall be inspected periodically and maintained in accordance withMaintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970. Building 25003, mechanical room: On or about 02 DEC 11, two fire extinguishers were not inspected and left on the floor by the door subjecting the fire extinguishers to foot traffic. Employees/plumbers used propane torch for soldering, brazing and joining copper pipes creating a fire hazard. None of the fire extinguishers received an annual inspection checked.
Recent events (1)
- — Z (S) $1620
1910.1200 E01 I
- Issued
- Feb 15, 2012
- Abate by
- Mar 8, 2012
- Penalty
- Initial $1,620 · Current $1,620
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present using an identity that was referenced on the appropriate material safety data sheet: (Construction Reference: 1926.59) Building 25003, mechanical room: On or about 02 DEC 11 and at times prior thereto, the inventory list was not provided for hazardous materials such as, but not limited to solder wire and solder flux, filler metals and propane among other hazardous materials. Note: the list must account for all the hazardous materials onsite and the material safety data sheets (MSDS)
Recent events (1)
- — Z (S) $1620
1910.1200 G01
- Issued
- Feb 15, 2012
- Abate by
- Feb 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical which they used: (Construction Reference: 1926.59) Building 25003, mechanical room: On or about 02 DEC 11 and at times prior thereto, material safety data sheets were not readily available for hazardous materials such as, but not limited to solder wires and solder fluxes, filler metals and propane among other hazardous materials.
Recent events (1)
- — Z (S) $0
1910.1200 H01
- Issued
- Feb 15, 2012
- Abate by
- Feb 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) Building 25003, mechanical room: On or about 02 DEC 11 and at times prior thereto, information and training was not provided for hazardous materials such as, but not limited to solder wires and solder fluxes, filler metals and propane among other hazardous materials.
Recent events (1)
- — Z (S) $0
More inspections at United Mechanical
View United Mechanical's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331099812.