Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G&D INTEGRATED MANUFACTURING LOGISTICS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of G&D INTEGRATED MANUFACTURING LOGISTICS, INC. in 1601 N. MAIN STREET, MORTON, IL 61550 (NAICS 333120). OSHA activity number 331101170.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G&D Integrated Manufacturing Logistics, INC. — free Get an email when a new federal OSHA severe-injury report for G&D Integrated Manufacturing Logistics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1601 N. MAIN STREET
City
MORTON
State
IL
ZIP
61550
Mailing
50 COMMERCE DRIVE, MORTON, IL 61550
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333120
Employees
181
Ownership type
A

6 citations on file for this inspection.

1910.176 B

Serious Gravity 5 15 exposed
Issued
May 25, 2012
Abate by
Jul 10, 2012
Penalty
Initial $4,000 · Current $2,800 Reduced
29 CFR 1910.176(b):   Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:    Employees in the NATA building stacked drive chains coming off of assembly onto the production floor at various heights next to forklift work areas without barriers or protection against collapse and previously installed racking for the chains had been removed.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

1910.179 G02 I

Serious Gravity 5 15 exposed
Issued
May 25, 2012
Abate by
Jul 10, 2012
Penalty
Initial $4,000 · Current $2,800 Reduced
29 CFR 1910.179(g)(2)(i):  Electrical equipment was not so located or enclosed that live parts would not be exposed to accidental contact under normal operating conditions:    Crane C-3 in the NATA Building was used daily to move various size drive chains and the crane was missing a brake cover so that the live wiring was exposed and the employer continued to operate the crane with this condition.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

1910.179 G02 II

Serious Gravity 5 15 exposed
Issued
May 25, 2012
Abate by
Jul 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.179(g)(2)(ii):   Electrical equipment was not protected from dirt, grease, oil, or moisture:    Crane C-3 in the NATA Building was used daily to move various size drive chains and the crane was missing a brake cover so that the live conductors were exposed to dirt and other types of contamination.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 H01 I

Serious Gravity 5 15 exposed
Issued
May 25, 2012
Abate by
Aug 20, 2012
Penalty
Initial $4,000 · Current $2,800 Reduced
29 CFR 1910.179(h)(1)(i):     Sheave grooves were not smooth and free from surface defects which could cause rope damage:    Crane C-1 in the NATA Building was used daily to move various size drive chains with a below-the-hook lifting device and the December 2011 periodic inspection found imprinting on the C-1 load block and the employer continued to operate the crane with this deficiency.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

1910.179 L03 I

Serious Gravity 10 15 exposed
Issued
May 25, 2012
Abate by
Aug 20, 2012
Penalty
Initial $7,000 · Current $4,300 Reduced
29 CFR 1910.179(l)(3)(i):  Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed:    Cranes in the NATA Building were used daily to move various size drive chains and the December 2011 periodic inspections found multiple items in need of repair or replacement and the employer continued to operate the crane before correcting the unsafe conditions.
Recent events (2)
  • — I (S) $4300
  • — Z (S) $7000

1910.179 L03 III

Serious Gravity 10 15 exposed
Issued
May 25, 2012
Abate by
Aug 20, 2012
Penalty
Initial $7,000 · Current $4,300 Reduced
29 CFR 1910.179(l)(3)(iii):   Repairs or replacements were not provided promptly as needed for safe operation of crane(s):    Cranes in the NATA Building were used daily to move various size drive chains and the December 2011 periodic inspections found multiple items in need of repair or replacement and the employer the repairs and replacements were not provided promptly.
Recent events (2)
  • — I (S) $4300
  • — Z (S) $7000

View G&D Integrated Manufacturing Logistics, INC.'s full OSHA safety record →