MORTON, IL —
OSHA Inspection: G&D INTEGRATED MANUFACTURING LOGISTICS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of G&D INTEGRATED MANUFACTURING LOGISTICS, INC. in 1601 N. MAIN STREET, MORTON, IL 61550 (NAICS 333120). OSHA activity number 331101170.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G&D INTEGRATED MANUFACTURING LOGISTICS, INC.
- Site address
- 1601 N. MAIN STREET
- City
- MORTON
- State
- IL
- ZIP
- 61550
- Mailing
- 50 COMMERCE DRIVE, MORTON, IL 61550
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333120
- Employees
- 181
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.176 B
- Issued
- May 25, 2012
- Abate by
- Jul 10, 2012
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: Employees in the NATA building stacked drive chains coming off of assembly onto the production floor at various heights next to forklift work areas without barriers or protection against collapse and previously installed racking for the chains had been removed.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.179 G02 I
- Issued
- May 25, 2012
- Abate by
- Jul 10, 2012
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.179(g)(2)(i): Electrical equipment was not so located or enclosed that live parts would not be exposed to accidental contact under normal operating conditions: Crane C-3 in the NATA Building was used daily to move various size drive chains and the crane was missing a brake cover so that the live wiring was exposed and the employer continued to operate the crane with this condition.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.179 G02 II
- Issued
- May 25, 2012
- Abate by
- Jul 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(g)(2)(ii): Electrical equipment was not protected from dirt, grease, oil, or moisture: Crane C-3 in the NATA Building was used daily to move various size drive chains and the crane was missing a brake cover so that the live conductors were exposed to dirt and other types of contamination.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 H01 I
- Issued
- May 25, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.179(h)(1)(i): Sheave grooves were not smooth and free from surface defects which could cause rope damage: Crane C-1 in the NATA Building was used daily to move various size drive chains with a below-the-hook lifting device and the December 2011 periodic inspection found imprinting on the C-1 load block and the employer continued to operate the crane with this deficiency.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.179 L03 I
- Issued
- May 25, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $7,000 · Current $4,300 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(i): Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed: Cranes in the NATA Building were used daily to move various size drive chains and the December 2011 periodic inspections found multiple items in need of repair or replacement and the employer continued to operate the crane before correcting the unsafe conditions.
Recent events (2)
- — I (S) $4300
- — Z (S) $7000
1910.179 L03 III
- Issued
- May 25, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $7,000 · Current $4,300 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(iii): Repairs or replacements were not provided promptly as needed for safe operation of crane(s): Cranes in the NATA Building were used daily to move various size drive chains and the December 2011 periodic inspections found multiple items in need of repair or replacement and the employer the repairs and replacements were not provided promptly.
Recent events (2)
- — I (S) $4300
- — Z (S) $7000
More inspections at G&D Integrated Manufacturing Logistics, INC.
View G&D Integrated Manufacturing Logistics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333120)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331101170.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.