OSHA Inspection: COMMERCIAL RESINS COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COMMERCIAL RESINS COMPANY in 8100 E. 96TH AVENUE, HENDERSON, CO 80640 (NAICS 325510). OSHA activity number 331102467.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Commercial Resins Company — free Get an email when a new federal OSHA severe-injury report for Commercial Resins Company is published. One employer, no account, unsubscribe in one click.
Site address
8100 E. 96TH AVENUE
City
HENDERSON
State
CO
ZIP
80640
Mailing
8100 E. 96TH AVENUE, HENDERSON, CO 80640
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
27
Ownership type
A

16 citations on file for this inspection.

1910.305 E01

Serious Gravity 1 2 instances 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.305(e)(1):  Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures:    (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure each energized conveyor outlet boxes, 110V, located on the pipe conveyors inside the shop were weather rated for damp or wet conditions. Boxes had water dripping onto them from the conveyor assembly.  This condition exposed the employees to electrical shock hazards.    (b)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure each energized conveyor outlet boxes, 110V, located on the pipe conveyors outside the shop were weather rated for damp or wet conditions. Boxes were exposed to outdoor weather conditions.  This condition exposed the employees to electrical shock hazards.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.26 C02 IV

Serious Gravity 1 1 instance 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.26 (c)(2)(iv):  The employer did not ensure portable metal ladders were maintained in good usable condition at all times:      (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the portable metal ladder in main production was maintained in good usable condition. The ladder was bent in on the landing step. Employees use the ladder daily to perform maintenance work.  This condition exposed employees to slip, trip, and fall hazards.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.212 A01

Serious Gravity 10 3 instances 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.212(a)(1):  Machine guarding was not provided to protect operators and other employees from hazards created by ingoing nip points, rotating parts, flying chips and sparks:    (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11,  guarding was not provided to protect employees from hazards created by the rotating horizontal shaft ends of the motor on the Wheelabrator (blast cleaning machine) A138363. One drive shaft end rotating at high rpm was exposed at the west rear end of the blast cleaning machine. This condition exposed employees to laceration and amputation hazards.    (b)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11,  guarding was not provided to protect employees from hazards created by the rotating chain on the side of the Wheelabrator (blast cleaning machine) A138363. The rotating chain is exposed through a square opening of approximately 6 X 12 on the west side of the blast cleaning machine. This condition exposed employees to laceration and amputation hazards.    (c)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, guarding was not provided to protect employees from hazards created by a extruding rotating horizontal shaft on the Wheelabrator (blast cleaning machine) A138363. The shaft is located towards the front west end of the blast cleaning machine. This condition exposed employees to laceration and amputation hazards.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.147 C01

Other-than-serious 1 instance 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.147(c)(1):  The employer did not establish a program consisting of energy control procedures and employee training to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated from the energy source, and rendered inoperative in accordance with 29 CFR 1910.147(c)(4):    (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not establish a program consisting of energy control procedures and employee training to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated from the energy source, and rendered inoperative, including but not limited to the following:    (1)  Wheelabrator A138363   (2)  Pipe Conveyor System (including incoming pipe, heating to 100 degrees, powder spray addition, water quench, holiday detection, and pipe inspection)
Recent events (2)
  • — I (O) $1750
  • — Z (S) $3500

1910.23 C03

Serious Gravity 10 2 instances 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.23(c)(3):  The employer did not provide a standard railing and toe board, regardless of height, on a open-sided floor above dangerous equipment:     (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not provide a standard railing and toe board, regardless of height, on the open-sided floor, 21'' deep, of the Wheelabrator A138363 blast cleaning machine. Below the open-sided floor is a high speed rotating shaft which is not guarded.   This condition exposed employees to fall, laceration and amputation hazards.    (b)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not provide a standard railing and toe board on the main floor at the end of pipe inspection, by the where the floor drops down by several inches. The walking-working surface is not even. This condition exposed employees to fall hazards.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.23 A09

Other-than-serious 1 instance 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.23 (a)(9):  The employer did not provide a floor hole cover into which employees can accidentally walk and that leaves no openings more than 1 inch wide.      (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not provide a floor hole cover over a stepped walk-way from one side of the pipe conveyor to the other side of the pipe conveyor. This condition exposed employees to fall hazards.
Recent events (2)
  • — I (O) $1050
  • — Z (S) $2100

1910.24 B

Serious Gravity 5 1 instance 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.24(b): The employer did not provide fixed stairs to access from one structure level to another where operations necessitated regular travel between levels,and for access to operating platforms at any equipment which requires attention routinely during operations:    (a)       Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not provide fixed stairs to access the elevated platform above the powder mix area. This platform is accessed daily or weekly using a step ladder to change out the filters. This condition exposed employees to fall hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.26 C03 VII

Serious 1 instance 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.26(c)(3)(vii): The employer did not ensure that a portable metal ladder was not used as a brace for other uses than that for which they were intended, unless specifically recommended for use by the manufacturer:    (a)       Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the portable metal step ladder was used for its intended use. The ladder, when fully extended, did not reach the platform above the powder mix area and thus employees were stepping on top of the ladder to access the platform. This condition exposed employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C01

Other-than-serious 2 instances 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.146 (c)(1):  The employer did not evaluate the workplace to determine if any spaces are permit-required confined spaces:     (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not evaluate the Wheelabrator A138363 blast cleaning machine to determine if it was a permit-required confined space. Employees perform maintenance work to the inside of the machine every weekend.  This condition exposed employees to asphyxiation hazards.    (b)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not evaluate the outside water cistern to determine if it was a permit-required confined space. Employees place a ladder inside of the cistern to clean and remove dirt. This condition exposed employees to asphyxiation hazards.
Recent events (2)
  • — I (O) $2450
  • — Z (S) $4900

1910.23 C01

Other-than-serious 4 instances 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1910.23 (c)(1):  The employer did not provide a guard by standard railing (or the open sides except where there is entrance to a ramp, stairway, or fixed ladder) on every open-sided floor or platform 4 feet or more above adjacent floor or ground level:     (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not provide a guardrail on an elevated loft floor of 8 feet or more. An section of the loft floor is not guarded. This condition exposed employees to fall hazards.    (b)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not provide a guardrail on an elevated platform used to get into rail cars to unload pipe. This condition exposed employees to fall hazards.    (c)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not provide a guardrail on an elevated platform used to change out filters for an expoxy powder product. This condition exposed employees to fall hazards.    (d)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not provide a guardrail on an elevated platform on top of the Wheelabrator A138363 blast cleaning machine while performing maintenance and welding work. This condition exposed employees to fall hazards.
Recent events (2)
  • — I (O) $2100
  • — Z (S) $4200

1910.305 A02 X

Other-than-serious 2 instances 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:     (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the flexible cord to the indoor conveyor outlet box near the pipe inspection area was protected from damage. The cord was frayed exposing the energized wiring. This condition exposed the employees to electrical shock and electrocution hazards.    (b)	 Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that employees using a power cord connected to the Blast Cleaning Machine were protected from electrical hazards in that, the insulated metal conduit protecting employees from coming into contact with the inner conductors was damaged.   The  conduit was open approximately 1/2 inch exposed the inner power cord. This condition exposed employees to burns, shock, and electrocution hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i):   Pull boxes, junction boxes, and outlet boxes in completed installations did not have a cover, faceplate, or fixture canopy approved for the purpose:    (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the energized conveyor outlet box, 110V,  located on the pipe conveyors outside and inside the shop had an effective cover plate. Wires were exposed from the inside of the conveyor outlet boxes. The junction box was missing the faceplate covering the box which exposed employees to live electrical equipment. This condition exposed the employees to electrical shock and electrocution hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii):  Unused openings in boxes, cabinets, or fittings were not effectively closed:     (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the openings on the main breaker switch on the electrical panel box located on the East wall of the conveyors were covered.  The non-metallic disconnect boxes had one hole approximately 1.5 diameter, exposing employees to 3 phase 480V live electrical equipment within the disconnect box. This condition exposed the employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 4 instances 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iii)(A):    Flexible cords and cables were being used as a substitute for the fixed wiring of the structure:    (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the indoor flexible cord being used to power an outdoor radio was from an approved receptacle outlet. A flexible cord was traced from inside the shop building to underneath the outdoor pipe conveyor and into a shed where a radio was being powered. This condition exposed the employees to electrical shock and electrocution hazards.    (b)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the flexible cord being used to power the boom box radio near the end of the pipe inspection was from an approved receptacle outlet. A flexible cord was traced from a junction box on the conveyor outlet to the radio resting on a portable computer cabinet. This condition exposed the employees to electrical shock and electrocution hazards.    (c)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the flexible cord being used to power the computer near the end of the pipe inspection was from an approved receptacle outlet. A flexible cord was traced from a junction box on the conveyor outlet to the computer resting on a portable computer cabinet. This condition exposed the employees to electrical shock and electrocution hazards.    (d)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the flexible cord being used to power the computer speakers near the end of the pipe inspection was from an approved receptacle outlet. A flexible cord was traced from a junction box on the conveyor outlet to the HP computer speakers resting on a portable computer cabinet. This condition exposed the employees to electrical shock and electrocution hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 A

Other-than-serious 2 instances 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $700 · Current $0 Reduced
29 CFR 1910.132(a):  Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure did not ensure that protective equipment was used in the following instance:  Employees were not using protective equipment while welding on top of the Wheelabrator A138363. This condition exposed employees to the hazards of falling.    (b)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure did not ensure that protective equipment was used in the following instance:  Employees were not using protective equipment while unloading pipe and rebar from on top of the railcars. This condition exposed employees to the hazards of falling.
Recent events (2)
  • — I (O) $0
  • — Z (O) $700

1910.110 D07

Other-than-serious 1 instance 12 exposed
Issued
May 4, 2012
Abate by
May 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.110 (d)(7):  The employer did not ensure that the propane fuel storage tank was installed on substantial masonry or noncombustible structural supports on firm masonry foundation:     (a)	Commercial Resins Company, 8100 E. 96th Ave, Henderson, CO 80640: On and before 12/14/11, the employer did not ensure that the 1,000 gallon propane storage tanks, outside near the west end of the building, was installed on substantial masonry. The tank is installed on concrete blocks. This condition exposed employees to explosion or burn hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Commercial Resins Company's full OSHA safety record →