Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VPP GROUP, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of VPP GROUP, LLC in 19087 HIGHWAY 71 EAST, NORWALK, WI 54648 (NAICS 311611). OSHA activity number 331103440.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VPP Group, LLC — free Get an email when a new federal OSHA severe-injury report for VPP Group, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VPP GROUP, LLC
Site address
19087 HIGHWAY 71 EAST
City
NORWALK
State
WI
ZIP
54648
Mailing
19087 HIGHWAY 71 EAST, NORWALK, WI 54648
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311611
Employees
111
Ownership type
A

13 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 1 instance 9 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.215(a)(4): On offhand grinding machines, work rests were not used to support the work. Work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage.     The employer did not adjust the work rest for the grinder to less than one-eighth inch between the grinding wheel and the rest.  Employees were exposed to being struck by flying abrasive wheel fragments.
Recent events (3)
  • — F (S) $2000
  • — C (S) $4000
  • — Z (S) $4000

1910.215 B09

Serious Gravity 5 1 instance 9 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Safety guards of the types described in Subparagraphs (3) and (4) of thisparagraph, where the operator stands in front of the opening, were not constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs(b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)    The distance between the adjustable tongue guard and the face of the grinding wheel of the pedestal grinder exceeded one-fourth inch.  Employees were exposed to being struck by flying abrasive wheel fragments.
Recent events (4)
  • — F (S) $0
  • — F (S) $0
  • — C (S) $0

1910.303 F02

Serious Gravity 5 1 instance 9 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $5,000 · Current $2,000 Reduced
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.    Maintenance Shop - The overcurrent devices (circuit breakers) contained within the panelboard were not legibly marked and others did not indicate their purposes.  Employees working on or near connected equipment were exposed to electrical hazards.
Recent events (3)
  • — F (S) $2000
  • — C (S) $5000
  • — Z (S) $5000

1910.304 G05

Serious Gravity 10 1 instance 9 exposed
Issued
Jun 7, 2012
Penalty
Initial $7,000 · Current $3,000 Reduced
29 CFR 1910.304(g)(5):  Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.      A fluorescent light fixture used on the kill floor was not grounded.  The equipment grounding conductor was not connected to the fixture.  Employees performing a repair in the immediate area were exposed to the hazard of electrocution.
Recent events (3)
  • — F (S) $3000
  • — C (S) $7000
  • — Z (S) $7000

1910.305 B02 I

Serious Gravity 5 2 instances 9 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    Employees were not protected from inadvertent contact with live (energized) parts above the kill floor where electrical conduit boxes were not enclosed or covered.  Employees were exposed to the hazard of electrocution.
Recent events (3)
  • — F (S) $2000
  • — C (S) $4000
  • — Z (S) $4000

1910.305 G01 IV A

Serious Gravity 5 1 instance 111 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $5,000 · Current $2,000 Reduced
29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure;      Temporary wiring was used by the employer to power lights and fans over the kill floor and throughout the facility.
Recent events (3)
  • — F (S) $2000
  • — C (S) $5000
  • — Z (S) $5000

1910.305 G02 III

Serious Gravity 10 2 instances 25 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $7,000 · Current $2,000 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.    (a)  No strain relief was provided for the Butcher Boy meat saw resulting in damage to the flexible cord from pull being transmitted to the joint where the cord entered and terminals in the box.    (b)  No strain relief was provided for a flexible cord supplying power to the fluoresent light fixture above the kill floor, resulting in pull being transmitted to the joint where the chord entered the fixture.
Recent events (3)
  • — F (S) $2000
  • — C (S) $7000
  • — Z (S) $7000

1910.333 A

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.333(a):     Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized.  The specific safety-related work practices were not consistent with the nature and extent of the associated electrical hazards.    Kill Floor - Employees were directed to repair a leaking water pipe above energized light fixtures and receptacle boxes that were not designated for use in wet locations.  The employer failed to employ the use of electrical protective equipment or lockout/tagout (safety-related work practices) to prevent indirect electrical contact with conductive surfaces of wet electrical equipment that could have been energized.  Employees were exposed to electric shock, burns and electrocution.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.335 A01 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards were not provided with or used electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to beperformed. Note: Personal protective equipment requirements are contained in subpart I of this part.    Employees were working near energized parts with potential electrical hazards while conducting maintenance on a water line above the kill floor and were not using electrical protective equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.132 A

Willful Gravity 10 1 instance 6 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $70,000 · Current $35,000 Reduced
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, nor maintained in a sanitary and reliable condition wherever necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.    Employees working over the kill floor were not protected from falling approximately 15 feet to the lower levels.  The employer failed to ensure the use of personal fall arrest equipment where necessary to protect employees while in the process of performing maintenance.
Recent events (3)
  • — F (W) $35000
  • — C (W) $70000
  • — Z (W) $70000

1910.305 E01

Serious Gravity 10 1 instance 111 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $70,000 · Current $7,000 Reduced
29 CFR 1910.305(e)(1):  Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures and were not mounted so there was at least 6.35-mm (0.25-in.) airspace between the enclosure and the wall or other supporting surface. The enclosures were not weatherproof in wet locations.    (a)  Kill Floor - Electrical boxes and fittings were installed in damp and wet locations.  Boxes allowed moisture and/or water to enter and accumulate.  Fittings also allowed moisture and/or water to enter and accumulate on and around energized conductors.  Employees who made inadvertent contact with the equipment and connected components were exposed to shock, burn and electrocution.    (b)  Head Room - Electrical boxes and fittings were installed in damp and wet locations.  Boxes allowed moisture and/or water to enter and accumulate.  Fittings also allowed moisture and/or water to enter and accumulate on and around energized conductors.  Employees who made inadvertent contact with the equipment and connected components were exposed to shock, burn and electrocution.
Recent events (3)
  • — F (S) $7000
  • — C (W) $70000
  • — Z (W) $70000

1910.305 J01 IV

Serious Gravity 10 1 instance 111 exposed
Issued
Jun 7, 2012
Abate by
Jun 8, 2012
Penalty
Initial $0 · Current $7,000
29 CFR 1910.305(j)(1)(iv):  Fixtures installed in wet or damp locations were not identified for the purpose and were not constructed or installed so that water cannot enter or accumulate in wireways, lampholders, or other electrical parts.    Kill Floor - Five lighting fixtures, installed in this wet locations were not identified for use in wet locations and allowed water to enter and accumulate around energized conductors and parts contained within the fixtures.  Employees who made inadvertent contact with the conductive surfaces of the fixtures and supporting structures were exposed to shock, burn and electrocution.
Recent events (3)
  • — F (S) $7000
  • — C (W) $0
  • — Z (W) $0

1910.147 C05 II

Other-than-serious 1 instance 111 exposed
Issued
Jun 7, 2012
Abate by
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the devices(s).    Boning Room - The lock used to lock out the skinner did not indicate the identity of the employee applying the lock.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View VPP Group, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331103440.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.