Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VPP GROUP, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VPP GROUP, LLC in 19081 HIGHWAY 71 EAST, NORWALK, WI 54648 (NAICS 311611). OSHA activity number 342839347.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VPP Group, LLC — free Get an email when a new federal OSHA severe-injury report for VPP Group, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VPP GROUP, LLC
Site address
19081 HIGHWAY 71 EAST
City
NORWALK
State
WI
ZIP
54648
Mailing
19081 HIGHWAY 71 EAST, NORWALK, WI 54648
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311611
Employees
147
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 15, 2018
Abate by
Feb 26, 2018
Penalty
Initial $8,315 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   On or about December 12, 2017 , and at times prior to, the employer failed to ensure that employees engaged in greasing the drive chain in the kill floor area did so utilizing a procedure to control potentially hazardous energy associated within the start up of the drive chain.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8315

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 15, 2018
Abate by
May 14, 2018
Penalty
Initial $11,641 · Current $8,315 Reduced
29 CFR 1910.147(d): 29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) covered the following elements, however, the actions were not done in sequence as required by 29 CFR 1910.147 (d)(1)-(6):    On or about December 12, 2017, and at times prior to, employees were exposed to machine hazards associated with moving parts and in-going nip points when they engaged in greasing of a drive chain in the kill floor area.  The employer did not ensure that employees implemented energy control application steps prior to allowing them to grease the drive chain.  The drive chain was not shut down or turned off prior to engaging in this servicing and maintenance activity.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $8315
  • — Z (S) $11641

View VPP Group, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342839347.