GREENWOOD, WI —
OSHA Inspection: DAIRICONCEPTS, L.P.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DAIRICONCEPTS, L.P. in W7014 HIGHWAY MM, GREENWOOD, WI 54437 (NAICS 311513). OSHA activity number 331107482.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAIRICONCEPTS, L.P.
- Site address
- W7014 HIGHWAY MM
- City
- GREENWOOD
- State
- WI
- ZIP
- 54437
- Mailing
- W7014 HIGHWAY MM, GREENWOOD, WI 54437
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311513
- Employees
- 28
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D04 I
- Issued
- Feb 8, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $4,400 · Current $4,400
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) At the capping machine, the centrifugal feeder and the form fill seal machine; The employees were clearing jams and removing caps without affixing a lockout tagout device in order to isolate energy sources.
Recent events (2)
- — I (O) $4400
- — Z (S) $4400
1910.147 C06 I
- Issued
- Feb 8, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Throughout the facility; The employer did not conduct periodic inspections of the energy control procedures at the facility.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Dairiconcepts, L.P.
View Dairiconcepts, L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 311513)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331107482.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.