EL DORADO SPRINGS, MO —
OSHA Inspection: DAIRICONCEPTS, L.P.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAIRICONCEPTS, L.P. in 305 WEST US HIGHWAY 54, EL DORADO SPRINGS, MO 64744 (NAICS 311514). OSHA activity number 334014222.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAIRICONCEPTS, L.P.
- Site address
- 305 WEST US HIGHWAY 54
- City
- EL DORADO SPRINGS
- State
- MO
- ZIP
- 64744
- Mailing
- 305 WEST US HIGHWAY 54, EL DORADO SPRINGS, MO 64744
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311514
- Employees
- 114
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Jun 27, 2012
- Abate by
- Jul 19, 2012
- Penalty
- Initial $2,295 · Current $500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) The employer had not conducted an inspection of their lockout tagout program on an annual basis since October 2010. Abatement documentation is required for this item.
Recent events (2)
- — I (O) $500
- — Z (S) $2295
1910.178 P01
- Issued
- Jun 27, 2012
- Abate by
- Aug 9, 2012
- Penalty
- Initial $3,060 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Where powered industrial trucks were found to be in need of repair, defective, or in any way unsafe, the trucks were not taken out of service until they had been restored to safe operating condition (a) A support for the forklift Falling Object Protection had been damaged and not repaired prior to returning to service. Abatement verification is required for this item.
Recent events (2)
- — I (O) $1000
- — Z (S) $3060
1910.242 B
- Issued
- Jun 27, 2012
- Penalty
- Initial $3,060 · Current $0 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) The air pressure to an air nozzle in the packaging area used for cleaning purposes, had not been reduced to less than 30 p.s.i. The air pressure to the nozzle was 45-50 p.s.i. Abatement verification for thids item is not required. Violation corrected at time of inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $3060
More inspections at Dairiconcepts, L.P.
View Dairiconcepts, L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 311514)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334014222.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.