MIDDLETOWN, OH —
OSHA Inspection: HONEY CELL INC. MIDWEST
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HONEY CELL INC. MIDWEST in 6480 HAMILTON LEBANON ROAD, MIDDLETOWN, OH 45044 (NAICS 322211). OSHA activity number 331109371.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HONEY CELL INC. MIDWEST
- Site address
- 6480 HAMILTON LEBANON ROAD
- City
- MIDDLETOWN
- State
- OH
- ZIP
- 45044
- Mailing
- 6480 HAMILTON LEBANON ROAD, MIDDLETOWN, OH 45044
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322211
- Employees
- 28
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 11, 2012
- Abate by
- Feb 24, 2012
- Penalty
- Initial $3,960 · Current $3,960
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) The written Lockout program/procedures were inadequate in that they did not spell out the requirement for the periodic or at least annual inspections of the energy control (lockout) procedures to have a certification record of each inspection and that the certification record contain, at a minimum, the name of the machine or equipment being locked out, the date of the inspection, the name of employee(s) included in the inspection, and the name of the person performing the inspection, plus the records must be retained.
Recent events (2)
- — I (S) $3960
- — Z (S) $3960
1910.147 C06 II
- Issued
- Jan 11, 2012
- Abate by
- Feb 24, 2012
- Penalty
- Initial $3,960 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) There were no certification records kept that documented that periodic or at least annual inspections of the energy control (lockout) procedures had been performed.
Recent events (2)
- — I (S) $0
- — Z (S) $3960
1910.147 C05 II
- Issued
- Jan 11, 2012
- Abate by
- Feb 24, 2012
- Penalty
- Initial $2,970 · Current $500 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were utilized for purposes other than controlling energy: (a) In the plant by the supervisor's office, there were two red lockout locks used on employee's lockers.
Recent events (2)
- — I (S) $500
- — Z (S) $2970
1910.305 B02
- Issued
- Jan 11, 2012
- Abate by
- Feb 24, 2012
- Penalty
- Initial $3,960 · Current $1,900 Reduced
General-duty citation text
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) In the plant outside the supervisor's office, there were two 120 VAC duplex outlets that were missing their faceplates.
Recent events (2)
- — I (S) $1900
- — Z (S) $3960
1910.212 A01
- Issued
- Jan 11, 2012
- Abate by
- Feb 24, 2012
- Penalty
- Initial $9,900 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by ingoing nip points, rotating parts, moving parts, pinch points, etc.: (a) On or about December 29, 2011, the Doall vertical band saw in the Fabrication area, was used without the ingoing nip points of the guide rollers and the unused portion of the blade above the guide rollers being guarded. Honey Cell Midwest, Inc. was previously cited for 29 CFR 1910.212(a)(1) or equivalent standard for a unguarded band saw contained within Inspection #312213846 (OIS# 91970), Serious Citation 1 Item 4 issued on 6/16/2008 and settled by a signed informal settlement agreement on 7/2/2008.
Recent events (2)
- — I (R) $4000
- — Z (R) $9900
More inspections at Honey Cell INC. Midwest
View Honey Cell INC. Midwest's full OSHA safety record →
More inspections in this industry (NAICS 322211)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331109371.