BENSENVILLE, IL —
OSHA Inspection: LAKE CABLE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LAKE CABLE, LLC in 529 THOMAS DRIVE, BENSENVILLE, IL 60106 (NAICS 332618). OSHA activity number 331901629.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAKE CABLE, LLC
- Site address
- 529 THOMAS DRIVE
- City
- BENSENVILLE
- State
- IL
- ZIP
- 60106
- Mailing
- 529 THOMAS DRIVE, BENSENVILLE, IL 60106
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 148
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C01
- Issued
- May 9, 2012
- Abate by
- May 31, 2012
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: The employer's energy control program was inadequate in that it allowed for multiple lockout devices (locks) to be keyed the same. Thus not affording complete employee protection from potential energy start up. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $4500
1910.147 C04 I
- Issued
- May 9, 2012
- Abate by
- Jun 7, 2012
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Maintenance employees perform work on machinery in the facility. Employees utilize lock out tag out but did not have documented procedures to follow. The employees are exposed to an unexpected startup of a machine if all sources of energy were not locked out. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $4500
1910.212 A03 II
- Issued
- May 9, 2012
- Abate by
- May 31, 2012
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: Employees were exposed to moving parts while changing the reels on the Dynamex Cablers. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $6300
1910.253 B04 III
- Issued
- May 9, 2012
- Abate by
- May 31, 2012
- Penalty
- Initial $2,700 · Current $2,700
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour. Oxygen and Acetylene cylinders stored in the maintenance area are not stored at least 20 feet apart or with a fire rated wall that would separate the cylinders. Employees are exposed to a fire hazard while working in the facility. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $2700
1910.335 A01 I
- Issued
- May 9, 2012
- Abate by
- Jun 7, 2012
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: Employees who perform live voltage testing up to 480V during preventative maintenance on machinery did not have the proper gloves, head protection, and appropriate face shields to prevent against electrical shock and burns. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $6300
1910.335 A02 I
- Issued
- May 9, 2012
- Abate by
- Jun 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts: Employees perform live voltage testing up to (480V) during preventative maintenance on machinery. The employer did not provide the appropriate tools for employees to perform their job duties. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $0
1910.332 B01
- Issued
- May 9, 2012
- Abate by
- May 31, 2012
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: Employees were not trained by the employer to recognize the hazardous of electricity and employees were not qualified to be working on voltage up to 480. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $6300
More inspections at Lake Cable, LLC
View Lake Cable, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331901629.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.