Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: VETERANS ADMINISTRATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VETERANS ADMINISTRATION in 916 WEST OWENS AVE, NORTH LAS VEGAS, NV 89030 (NAICS 923120). OSHA activity number 331905984.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veterans Administration for free Get an email when a new federal OSHA severe-injury report for Veterans Administration is published. One employer, no account, unsubscribe in one click.
Site address
916 WEST OWENS AVE
City
NORTH LAS VEGAS
State
NV
ZIP
89030
Mailing
2100 EAST CALVADA BOULEVARD, PAHRUMP, NV 89048
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
923120
Employees
400
Ownership type
Federal government (D)

3 citations on file for this inspection.

1910.303 B01 II

Serious Gravity 5 2 instances 15 exposed
Issued
Jun 21, 2012
Abate by
Jul 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    (a) At the VA bldg. 916, conference room 201, and bldg. 950, break room 118, duplex convenience receptacle outlet covers were broken or cracked.
Recent events (1)
  • · Z (S) $0

1910.303 F02

Serious Gravity 5 1 instance 15 exposed
Issued
Jun 21, 2012
Abate by
Jul 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2):  Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.    (a) At the VA clinic, group conference room 171, electrical power panel LP-4, not all circuit breakers were labeled.
Recent events (1)
  • · Z (S) $0

1910.305 A02 X

Serious Gravity 1 1 instance 15 exposed
Issued
Jun 21, 2012
Abate by
Jun 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x):   Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.    (a) At the VA clinic, x-ray room, the flexible power cord of the x-ray generator was run through the door way.
Recent events (1)
  • · Z (S) $0

View Veterans Administration's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331905984.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.