MIDDLETON, WI —
OSHA Inspection: QUEST BUILDING CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QUEST BUILDING CORPORATION in 652 BEAR CLAW WAY, MIDDLETON, WI 53562 (NAICS 236115). OSHA activity number 331906271.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUEST BUILDING CORPORATION
- Site address
- 652 BEAR CLAW WAY
- City
- MIDDLETON
- State
- WI
- ZIP
- 53562
- Mailing
- 1032 QUINN DRIVE, WAUNAKEE, WI 53597
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 13
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 G01
- Issued
- Feb 14, 2012
- Abate by
- Feb 15, 2012
- Penalty
- Initial $3,300 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. Employees utilizing scaffolding during truss installation were exposed to fall hazards of a height greater than ten feet to the exterior of the building.
Recent events (2)
- — I (S) $1000
- — Z (S) $3300
1926.501 B01
- Issued
- Feb 14, 2012
- Abate by
- Feb 15, 2012
- Penalty
- Initial $9,240 · Current $3,080 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Employees attaching roof trusses at a height greater than six feet were doing so without fall protection. Quest Building Corporation, was previously cited for a violation of this or its equivalent Occupational Safety and Health Standard 29 CFR 1926.501b)(13), which was contained in OSHA Inspection Number 310766704, Citation Number 1, Item Number 5, Issued on 7/16/2008, and was affirmed final order on 7/31/2008, with respect to a workplace located at West End Properties, Verona, WI 53593.
Recent events (2)
- — I (R) $3080
- — Z (R) $9240
1926.1428 A03
- Issued
- Feb 14, 2012
- Abate by
- Feb 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1428(a)(3): The employer did not make the documentation for whichever option is used available at the site while the signal person is employed by the employer. The documentation did not specify each type of signaling (e.g. hand signals, radio signals, etc.) for which the signal person meets the requirements of paragraph (c) of this section. The employer did not prepare / maintain documentation pertaining to Signal Person Qualifications.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Quest Building Corporation
View Quest Building Corporation's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331906271.