Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: LOCKHEED MARTIN, RTS-MEDICAL-CAMP PARKS, CSTC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LOCKHEED MARTIN, RTS-MEDICAL-CAMP PARKS, CSTC in GROUND MAINTENANCE SHOP, BLDG. 862 CAMP PARKS, DUBLIN, CA 94568 (NAICS 811310). OSHA activity number 331910646.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lockheed Martin, Rts-Medical-Camp Parks, Cstc for free Get an email when a new federal OSHA severe-injury report for Lockheed Martin, Rts-Medical-Camp Parks, Cstc is published. One employer, no account, unsubscribe in one click.
Site address
GROUND MAINTENANCE SHOP, BLDG. 862 CAMP PARKS
City
DUBLIN
State
CA
ZIP
94568
Mailing
CAMP PARKS, BUILDING 800 RTS-MEDICAL-CAMP PARKS, CSTC, DUBLIN, CA 94568
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
32
Ownership type
A

5 citations on file for this inspection.

1910.178 G01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Mar 19, 2012
Abate by
Apr 30, 2012
Penalty
Initial $2,250 · Current $0 Reduced
29 CFR 1910.178(g)(1): Any power-operated industrial truck not in safe operating condition was not  removed from service:    (a) In the motor pool area for the ground maintenance shop on or about February 9, 2012, and at times prior there to, the horn did not function on a forklift, model number M4K, serial number 0150152.  It was used to lift pallets in the area.  There was no tag on the truck to indicate it was out of service or not to be operated.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2250

1910.215 B09

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 19, 2012
Abate by
Mar 22, 2012
Penalty
Initial $2,250 · Current $2,250
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, was not constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel.     The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch:    (a) In the ground maintenance shop on or about February 9, 2012, and at times prior thereto, there was no tongue guards on a Central Machinery 8 inch bench grinder.  The grinder's 8.75 inch by 5/8 inch abrasive wheel was used to grind small metal parts such as equipment switch covers.
Recent events (2)
  • · I (S) $2250
  • · Z (S) $2250

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Mar 19, 2012
Abate by
Apr 30, 2012
Penalty
Initial $2,250 · Current $1,575 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:    (a) In the ground maintenance shop on or about February 9, 2012, and at times prior thereto, electrical equipment was not used as designed to be used as a surge bar was used to power 110 VAC Dayton drill press and a Central Machinery bench grinder.
Recent events (2)
  • · I (O) $1575
  • · Z (S) $2250

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Mar 19, 2012
Abate by
Mar 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure;    (a) In the ground maintenance shop on or about February 9, 2012, and at times prior thereto, permanent wiring was not used to power permanently mounted 110 VAC Dayton drill press and a Central Machinery bench grinder.  The equipment was powered through a reel up extension cord and a surge bar.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.334 A02 II

Other-than-serious 1 instance 3 exposed
Issued
Mar 19, 2012
Abate by
Apr 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii):  When there was a defect or evidence of damage that might expose an employee to injury, the defective or damaged item was not removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe were made.    (a) In the ground maintenance shop on or about February 9, 2012, and at times prior thereto, electrical equipment with a damaged cord was used as the outer insulation was pulled away from the plug on a surge bar, used to power 110 VAC Dayton drill press and a Central Machinery bench grinder.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

View Lockheed Martin, Rts-Medical-Camp Parks, Cstc's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331910646.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.