Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PANDL PROPERTIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PANDL PROPERTIES, INC. in 5805 WEST HIGHWAY 161, BELLEVILLE, IL 62223 (NAICS 485320). OSHA activity number 331910653.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pandl Properties, INC. — free Get an email when a new federal OSHA severe-injury report for Pandl Properties, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5805 WEST HIGHWAY 161
City
BELLEVILLE
State
IL
ZIP
62223
Mailing
5805 WEST HIGHWAY 161, BELLEVILLE, IL 62223
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
485320
Employees
4
Ownership type
A

7 citations on file for this inspection.

1910.244 A01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2012
Abate by
Apr 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.244(a)(1)(ii):     Rated load(s) of portable jack(s) were not legibly and permanently marked in a prominent location on the jack(s) by casting, stamping, or other suitable means:        In the Garage, on the east wall, the red Snap On floor hydraulic jack, and the grey Speedy Lift floor hydraulic jack, did not have load ratings attached to them nor were not readable, exposing employees to crushing hazards by overloading the jacks while attempting to lift more that they are rated for.
Recent events (1)
  • — Z (S) $0

1910.244 A02 III

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 16, 2012
Abate by
Apr 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.244(a)(2)(iii):     Loads were not cribbed, blocked or otherwise secured immediately after being raised with a jack:      On or about December 13, 2011, at the facility, while working on a bus, an employee was exposed to crushing injuries when the bus they were working on fell when a jack failed to hold the load and the employee was beneath a part of the vehicle.  The bus had not been cribbed, blocked or secure to prevent the load from falling in case of the hydraulic jack failing.
Recent events (1)
  • — Z (S) $0

1910.304 G05

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 16, 2012
Abate by
Apr 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5):     The paths to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective;      On the 110 volt orange extension cord, plug into a receptacle on the north wall, supplying power to the battery charger in the lot area north of the garage, the ground plug was missing.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV C

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 16, 2012
Abate by
Apr 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(C):     Flexible cords and cables were run through doorways, windows, or similar openings:      The 110 volt orange extension cord, supplying power to the battery charger in the lot area north of the garage, was run through the door way on the north wall, exposing it to damage that could expose employees to an energized door/building hazard.
Recent events (1)
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 16, 2012
Abate by
Apr 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i):     Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):      North Lot, on two 110 volt orange extension cords, and the battery charger, the outer insulation was pulled out of the plug, allowing any strain to be placed onto the electrical wiring and connections.  The cords were in use and were supplying 110 volt power to the battery charger.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Apr 16, 2012
Abate by
May 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1):     Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):       A written Hazard Communications program regarding hazardous chemicals had not been developed to protect employees against chemicals hazards.  Employees who worked with hazardous chemicals such as but not limited to automotive oils, brake fluid, paints, primers, and motor degreasers were exposed to the hazards associated with those products.
Recent events (1)
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Apr 16, 2012
Abate by
May 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1):     Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:      Employees had not been trained regarding the hazards related with using hazardous chemicals such as but not limited to automotive oils, brake fluid, paints, primers, and motor degreasers were exposed to the hazards associated with those products.
Recent events (1)
  • — Z (O) $0

View Pandl Properties, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331910653.