DELTA, OH —
OSHA Inspection: MAVEN SOLUTIONS, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MAVEN SOLUTIONS, LLC in 6420 ROGERS RD., DELTA, OH 43515 (NAICS 332111). OSHA activity number 331911479.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAVEN SOLUTIONS, LLC
- Site address
- 6420 ROGERS RD.
- City
- DELTA
- State
- OH
- ZIP
- 43515
- Mailing
- 6420 ROGERS RD., DELTA, OH 43515
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 22
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.134 H01
- Issued
- Jul 10, 2012
- Abate by
- Aug 17, 2012
- Penalty
- Initial $1,980 · Current $990 Reduced
General-duty citation text
29 CFR 1910.134(h)(1): The employer did not provide each respirator user with a respirator that was clean, sanitary, and in good working order. The employer did not ensure that respirators were cleaned and disinfected using the procedures in Appendix B-2 of this section, or procedures recommended by the respirator manufacturer, provided that such procedures are of equivalent effectiveness. a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure the air supplied welding hood loose fitting respirator was clean and sanitary. The respirator was covered in dust when the employer brought it out of the respirator storage cabinet.
Recent events (2)
- — I (S) $990
- — Z (S) $1980
1910.134 K01
- Issued
- Jul 10, 2012
- Abate by
- Aug 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not ensure that each employee can demonstrate knowledge of at least the following: a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure an employee who was required to wear a half mask tight fitting respirator while performing galvanized steel welding operations was provided with information and training on the following: 1. How to inspect, put on, remove, use, and check the seals of the respirator; 2. What the procedures are for maintenance and storage of the espirator; 3. How to recognize the medical signs and symptoms that may limit the effective use of the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 Q01
- Issued
- Jul 10, 2012
- Penalty
- Initial $3,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not removed from service. All repairs shall be made by authorized personnel. a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the Yale forklift model #GLC050VXNVSQ088, was being operated with a malfunctioning parking brake and was not removed from service. b. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the Yale forklift model #GLP060VXEUSE091, was being operated with a malfunctioning parking break and was not removed from service.
Recent events (2)
- — I (S) $0
- — Z (S) $3300
1910.254 B04 IV
- Issued
- Jul 10, 2012
- Abate by
- Aug 17, 2012
- Penalty
- Initial $3,300 · Current $1,650 Reduced
General-duty citation text
29 CFR 1910.254(b)(4)(iv): Terminals for welding leads were not protected from accidental electrical contact by personnel or by metal objects i.e., vehicles, crane hooks, etc. Protection was not obtained by use of: Dead-front receptacles for plug connections; recessed openings with nonremovable hinged covers; heavy insulating sleeving or taping or other equivalent electrical and mechanical protection. If a welding lead terminal which is intended to be used exclusively for connection to the work is connected to the grounded enclosure, it was not done by a conductor at least two AWG sizes smaller than the grounding conductor and the terminal shall be marked to indicate that it is grounded. a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure the terminal connections for the welding leads on the Mille Deltaweld 452 wire welders were covered to prevent accidental contact.
Recent events (2)
- — I (S) $1650
- — Z (S) $3300
1910.305 B01 I
- Issued
- Jul 10, 2012
- Abate by
- Aug 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed. a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure the electrical cord leading to a knockout box used to power a plasma cutter located near welding cell #5 was protected from abrasion where the cord entered the box.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Jul 10, 2012
- Abate by
- Aug 17, 2012
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling. a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure the knockout box used to supply electrical power to the plasma cutter in weld station #5 was used according to its listing. The knockout box was designed to be mounted on or in a wall and was not designed to be exposed to damage.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1910.134 E01
- Issued
- Jul 10, 2012
- Abate by
- Jul 17, 2012
- Penalty
- Initial $3,960 · Current $1,980 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure an employee wearing a tight fitting North half mask respirator, Model 7190N99, while welding on galvanized steel, was provided with a medical evaluation prior to wearing the respirator. b. Maven Solutions, LLC located in Delta, Ohio: On or about April 9, 2012, the employer did not ensure an employee wearing a Miller Elite loose fitting powered air purifying respirator while welding on galvanized steel, was provided with a medical evaluation prior to wearing the respirator. Maven Solutions, LLC formerly known as Product Movers, LLC, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(e)(1), which was contained in OSHA Inspection Number 313786394, citation number 1, item number 1 and was affirmed as a final order on April 2, 2011, with respect to a workplace located at 6420 Rogers Rd., Delta, Ohio.
Recent events (2)
- — I (R) $1980
- — Z (R) $3960
1910.134 F01
- Issued
- Jul 10, 2012
- Penalty
- Initial $132 · Current $132
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph. a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure an employee wearing a tight fitting North half mask respirator, Model 7190N99, while welding on galvanized steel, was properly fit tested prior to wearing the respirator. Maven Solutions, LLC formerly known as Product Movers, LLC, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(f)(1), which was contained in OSHA Inspection Number 313786394, citation number 2, item number 2 and was affirmed as a final order on April 2, 2011, with respect to a workplace located at 6420 Rogers Rd., Delta, Ohio.
Recent events (2)
- — I (R) $132
- — Z (R) $132
1910.178 Q07
- Issued
- Jul 10, 2012
- Penalty
- Initial $6,600 · Current $3,478 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination was not made at least daily. Where industrial trucks are used on a round-the-clock basis, they were not examined after each shift. Defects when found were not immediately reported and corrected. a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure forklifts were inspected daily. The #2 Yale forklift serial number A910V04136C was being driven with an inoperable parking brake. b. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure forklifts were inspected daily. The #2 Yale forklift serial number B875B03185D was being driven with an inoperable parking brake. Maven Solutions, LLC formerly known as Product Movers, LLC, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.178(q)(7), which was contained in OSHA Inspection Number 313786402, citation number 1, item number 2 and was affirmed as a final order on April 2, 2011, with respect to a workplace located at 6420 Rogers Rd., Delta, Ohio.
Recent events (2)
- — I (S) $3478
- — Z (R) $6600
1910.252 B02 I A
- Issued
- Jul 10, 2012
- Abate by
- Aug 17, 2012
- Penalty
- Initial $7,200 · Current $3,478 Reduced
8370
General-duty citation text
29 CFR 1910.252(b)(2)(i)(A): Helmets or hand shields were not used during all arc welding or arc cutting operations, excluding submerged arc welding. Helpers or attendants shall be provided with proper eye protection. a. Maven Solutions, LLC located in Delta, Ohio: On or about April 9, 2012, the employer did not ensure employees performing gas shielded tack welding operations in the shop area were using their welding helmets. Employees were exposed to eye injuries from ultraviolet and infrared radiation. Maven Solutions, LLC formerly known as Product Movers, LLC, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.252(b)(2)(i)(A), which was contained in OSHA Inspection Number 313786394, citation number 1, item number 3 and was affirmed as a final order on April 2, 2011, with respect to a workplace located at 6420 Rogers Rd., Delta, Ohio.
Recent events (2)
- — I (R) $3478
- — Z (R) $7200
1910.252 B02 III
- Issued
- Jul 10, 2012
- Abate by
- Aug 17, 2012
- Penalty
- Initial $7,200 · Current $3,478 Reduced
8370
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Where the work permits, the welder was not enclosed in an individual booth painted with a finish of low reflectivity such as zinc oxide (an important factor for absorbing ultraviolet radiations) and lamp black, or was not enclosed with noncombustible screens similarly painted. Booths and screens shall permit circulation of air at floor level. Workers or other persons adjacent to the welding areas were not protected from the rays by noncombustible or flameproof screens or shields or were not required to wear appropriate goggles. a. Maven Solutions, LLC located in Delta, Ohio: On or about February 10, 2012, the employer did not ensure employees working adjacent to welding operations throughout the weld shop were protected from arc welding rays. Maven Solutions, LLC formerly known as Product Movers, LLC, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.252(b)(2)(iii), which was contained in OSHA Inspection Number 313786402, citation number 1, item number 2 and was affirmed as a final order on April 2, 2011, with respect to a workplace located at 6420 Rogers Rd., Delta, Ohio.
Recent events (2)
- — I (S) $3478
- — Z (R) $7200
More inspections at Maven Solutions, LLC
View Maven Solutions, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332111)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331911479.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.